2006
DOI: 10.1063/1.2186212
|View full text |Cite
|
Sign up to set email alerts
|

Beam-single and beam-two-foil experimental facility to study physics of highly charged ions

Abstract: Formation of doubly positively charged diatomic ions of Mo 2 2+ produced by Ar + sputtering of an Mo metal surface Resonance ionization spectroscopy investigations of electronic processes during ion-beam sputtering of metal atoms AIP Conf.A facility for lifetime measurement of metastable states in highly charged ions using the beam-foil technique with a single-foil and a two-foil target has been developed. In the two-foil technique, one foil moves with respect to the other and the option of varying the thickne… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
6
0

Year Published

2009
2009
2014
2014

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…However, this technique suffers from inherent cascading and blending problems. 3 By combining beam single foil and beam two foil techniques, Ahmad et al 4 have shown that the above mentioned complexity can be disentangled to a certain extent. 5 The Doppler tuned spectrometer (DTS) 6, 7 is a high resolution, high efficiency setup and hence suitable for the study of x-ray emission from metastable states, created by beam-foil interaction.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…However, this technique suffers from inherent cascading and blending problems. 3 By combining beam single foil and beam two foil techniques, Ahmad et al 4 have shown that the above mentioned complexity can be disentangled to a certain extent. 5 The Doppler tuned spectrometer (DTS) 6, 7 is a high resolution, high efficiency setup and hence suitable for the study of x-ray emission from metastable states, created by beam-foil interaction.…”
mentioning
confidence: 99%
“…A unique Soller slit assembly coupled with a long one dimensional position sensitive proportional counter enables us to get distinct x-ray peaks at different angles, which allows us to cover large number of angle in one shot. By using this setup, 1s2s 3 S 1 -1s 2 1 S 0 M1 transition in He-like Fe has been resolved from its satellite line 1s2s2p 4 The beam-foil spectroscopic (BFS) 1, 2 technique is one of the most elegant tools to study highly charged ions (HCI). However, this technique suffers from inherent cascading and blending problems.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The experiment was performed using the 15 UD tandem Pelletron accelerator at IUAC, New Delhi. A schematic of the experimental setup used is shown in the inset of figure 1 and details are given elsewhere (Ahmad et al 2006). A beam of 48 22 Ti 11+ at 143 MeV was passed through a carbon foil of about 60 μg cm −2 (first foil) to produce the excited states in highly charged ions.…”
mentioning
confidence: 99%
“…The agreement between the two methods was found within less than 10%. The flat carbon foils were fabricated by a special technique (Ahmad et al 2006) so that a capacitance-measuring arrangement can be used to measure the distance between the two parallel foils up to 83 ± 1 μm. The maximum distance was used up to 40 mm.…”
mentioning
confidence: 99%