2021
DOI: 10.1186/s12885-021-07991-6
|View full text |Cite
|
Sign up to set email alerts
|

Beam complexity and monitor unit efficiency comparison in two different volumetric modulated arc therapy delivery systems using automated planning

Abstract: Background To investigate the beam complexity and monitor unit (MU) efficiency issues for two different volumetric modulated arc therapy (VMAT) delivery technologies for patients with left-sided breast cancer (BC) and nasopharyngeal carcinoma (NPC). Methods Twelve left-sided BC and seven NPC cases were enrolled in this study. Each delivered treatment plan was optimized in the Pinnacle3 treatment planning system with the Auto-Planning module for the… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 30 publications
0
4
0
Order By: Relevance
“… 32 The key factors that are closely related to plan robustness and plan complexity should be clarified, such as modulation complexity scores (MCS), MLC aperture area variability (AAV), MLC leaf sequence variability (LSV), modulation index (MI), aperture area (AA), aperture perimeter (AP), aperture irregularity (AI), irregularity (PI), and plan-averaged beam modulation (PM) and so on, to interfere with plan quality and robustness. 33 , 34 …”
Section: Discussionmentioning
confidence: 99%
“… 32 The key factors that are closely related to plan robustness and plan complexity should be clarified, such as modulation complexity scores (MCS), MLC aperture area variability (AAV), MLC leaf sequence variability (LSV), modulation index (MI), aperture area (AA), aperture perimeter (AP), aperture irregularity (AI), irregularity (PI), and plan-averaged beam modulation (PM) and so on, to interfere with plan quality and robustness. 33 , 34 …”
Section: Discussionmentioning
confidence: 99%
“…[41][42][43] In the planning process, the plan complexity increases as the minimum segment area decreases and the number of optimization iterations and the maximum number of segments increases. [42] Therefore, excessive complex plans can lead to dose calculation and delivery uncertainties [44][45][46][47] and a decrease in treatment efficiency. [40] In addition, patient respiratory movements and gastrointestinal motility can also affect the accuracy of dose delivery by producing effects such as the Interplay effect.…”
Section: Plan Complexitymentioning
confidence: 99%
“…The treatment planning term describes the whole technical process, from patient data acquisition to treatment verification. There are many techniques to deliver the radiation dose to the tumor [6,7]. Intensity-Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) are modern planning approaches that combine linear accelerators to safely deliver precision radiation to a tumor while limiting the exposure to surrounding normal tissue.…”
Section: Introductionmentioning
confidence: 99%