2018
DOI: 10.1007/s10751-018-1539-6
|View full text |Cite
|
Sign up to set email alerts
|

Beam-based alignment tests at the Cooler Synchrotron (COSY)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 1 publication
0
7
0
Order By: Relevance
“…The S-BPMs will be used to reduce the external B-field and the magnetic quadrupole position tolerance by modulating the vertical tune and by using beam-based alignment. [36,37]…”
Section: Ring Lattice Designmentioning
confidence: 99%
See 1 more Smart Citation
“…The S-BPMs will be used to reduce the external B-field and the magnetic quadrupole position tolerance by modulating the vertical tune and by using beam-based alignment. [36,37]…”
Section: Ring Lattice Designmentioning
confidence: 99%
“…The total experiment duration is assumed to be 4 × 10 7 s, meaning approximately 4 × 10 4 fills, resulting to an unwanted maximum vertical spin precession rate of ≈ 0.75 nrad/s, corresponding to an EDM of 0.75×10 −29 e•cm in the same ring. A 10µm resolution in the position of the quadrupoles has been demonstrated using beam-based alignment in DC-mode in hadronic storage rings [37], while the S-BPMs and the method we have developed to probe the average separation of the CR beams, have much better resolution than that.…”
Section: Position Tolerances Of Ring Elementsmentioning
confidence: 99%
“…[13,Historical background] At present, a number of studies with polarized beams are carried out at COSY with the upshot of developing a future EDM experiment for an electrostatic storage ring. [36,37,15,38,39,40] In most studies, parameters summarized in Table 3.1 are used. The author would like to highlight the following technologies developed…”
Section: Formulation Bmentioning
confidence: 99%
“…Beam Based Alignment [40] is a procedure to verify that the beam passes through the center of a quadrupole. In order to so do, one varies the strength of the quadrupole and observes the changes this affects in the closed orbit.…”
Section: Beam Based Alignmentmentioning
confidence: 99%
“…Several tests were performed to determine the effect of a full beambased alignment survey of all quadrupoles in the accelerator. The first two tests [8,9] showed that the offset between the quadrupoles and BPMs amounts to several mm. Thus the beam-based alignment measurement has to be performed for all quadrupoles in the accelerator in order to have all BPMs properly calibrated.…”
Section: Introductionmentioning
confidence: 99%