Beam-based alignment at the Cooler Synchrotron COSY as a prerequisite for an electric dipole moment measurement

Abstract: The Jülich Electric Dipole moment Investigation (JEDI) collaboration aims at a direct measurement of the Electric Dipole Moment (EDM) of protons and deuterons using a storage ring. The measurement is based on a polarization measurement. In order to reach highest accuracy, one has to know the exact trajectory through the magnets, especially the quadrupoles, to avoid the influence of magnetic fields on the polarization vector. In this paper, the development of a beam-based alignment technique is described … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 12 publications
(16 reference statements)
0
5
0
Order By: Relevance
“…The calculations were performed for EDM values of D = 0, 10 −20 , 10 −19 , 5 × 10 −19 10 −18 e • cm for each misalignments setting. Additionally, similar calculations were performed for quadrupole magnet misalignments (only translation in all directions) being measured recently by the Vermessungsbüro Stollenwerk & Burghof [33]. These results for Fourier amplitudes are presented in table 2 for few EDM values.…”
Section: Determination Of the Edm Limit By Fourier Analysismentioning
confidence: 81%
See 2 more Smart Citations
“…The calculations were performed for EDM values of D = 0, 10 −20 , 10 −19 , 5 × 10 −19 10 −18 e • cm for each misalignments setting. Additionally, similar calculations were performed for quadrupole magnet misalignments (only translation in all directions) being measured recently by the Vermessungsbüro Stollenwerk & Burghof [33]. These results for Fourier amplitudes are presented in table 2 for few EDM values.…”
Section: Determination Of the Edm Limit By Fourier Analysismentioning
confidence: 81%
“…In addition to this orbit correction, a beam-based alignment procedure [32,33] enabling to align all 56 magnetic centers of the quadrupole magnets with the use of the 31 BPM's was recently performed at COSY. With this procedure, the beam was aligned with respect to the centre of the quadrupole magnets with a precision of 40 μm, while the quadrupole magnets are aligned to a precision of 200 μm to the design beam axis.…”
Section: Orbit Correctionmentioning
confidence: 99%
See 1 more Smart Citation
“…• beam based alignment to ensure a passage of the orbit through the center of the quadrupole magnets has been realized [342].…”
Section: Main Results Of Jedi Collaboration and Protonmentioning
confidence: 99%
“…In parallel, new technical equipment has been developed and installed in the COSY ring [12][13][14][15][16]. Systematic studies on ring imperfections and spin dynamics [17][18][19][20], beam-based alignment [21], and techniques that allow for the systematic evaluation of uncertainties [22] completed these investigations. All the experimental work was accompanied by theoretical studies and lattice simulations of spin and particle tracking [23,24].…”
Section: Introductionmentioning