2012
DOI: 10.1016/j.cbpa.2012.01.010
|View full text |Cite
|
Sign up to set email alerts
|

Baseline haptoglobin concentrations are repeatable and predictive of certain aspects of a subsequent experimentally-induced inflammatory response

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
153
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 99 publications
(154 citation statements)
references
References 42 publications
0
153
0
Order By: Relevance
“…For haptoglobin-like activity, a '405 nm pre-scan value' was added as a covariate to correct for plasma redness (after [23], who corrected at 450 nm). Model selection was done using stepwise backward elimination of non-significant terms ( p .…”
Section: (C) Data Analysismentioning
confidence: 99%
“…For haptoglobin-like activity, a '405 nm pre-scan value' was added as a covariate to correct for plasma redness (after [23], who corrected at 450 nm). Model selection was done using stepwise backward elimination of non-significant terms ( p .…”
Section: (C) Data Analysismentioning
confidence: 99%
“…Haptoglobin is a heme-binding acutephase protein with multiple physiological functions (Quaye 2008), including preventing free heme from serving as a nutrient for infectious microorganisms (Eaton et al 1982). Compared to agglutination titers, haptoglobin concentrations are considerably more labile over short timescales (van de Crommenacker et al 2010;Matson et al 2012aMatson et al , 2012b. A growing body of research explores both indexes in the contexts of avian ecology (Hegemann et al 2012;Horrocks et al 2012b), life history (Palacios et al 2007;Versteegh et al 2012), and geography (Matson 2006;Horrocks et al 2012a).…”
Section: Immunological Indexesmentioning
confidence: 98%
“…First, we measured concentrations (mg mL ÏȘ1 ) of plasma haptoglobin (Quaye 2008) using a commercially available colorimetric assay (TP801; Tridelta Development, Maynooth, County Kildare, Ireland; Matson et al 2012b). Ten haptoglobin assay plates used in this study included an among-plate standard, which was run in duplicate within each plate (mean amongplate coefficient of variation [CV] p 15%; mean within-plate CV p 10%).…”
Section: Immunological Indexesmentioning
confidence: 99%
“…Haptoglobin (Hp) belongs to the category of acute phase proteins and is used as a marker to measure the intensity of the inflammatory response in vertebrates, including birds (Matson et al, 2006(Matson et al, , 2012. The production of this protein by the liver is stimulated by activated inflammatory cytokines (Dobryszycka, 1997), so as the amount of plasma Hp increases, the inflammatory reaction becomes stronger.…”
Section: Haptoglobin Assaymentioning
confidence: 99%