2022
DOI: 10.1016/s0140-6736(22)01845-1
|View full text |Cite
|
Sign up to set email alerts
|

Balloon catheters versus vaginal prostaglandins for labour induction (CPI Collaborative): an individual participant data meta-analysis of randomised controlled trials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
18
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 31 publications
0
18
0
Order By: Relevance
“…Single‐balloon catheter is at least comparable to double‐balloon catheter and offers associated cost reductions to healthcare services. We recently demonstrated in another IPD‐MA that balloon catheters (single and double combined) and vaginal prostaglandins have comparable cesarean delivery rates and maternal safety profiles, but balloon catheters lead to fewer adverse perinatal events 27 . Therefore, balloon catheters should be used more widely in labor induction.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Single‐balloon catheter is at least comparable to double‐balloon catheter and offers associated cost reductions to healthcare services. We recently demonstrated in another IPD‐MA that balloon catheters (single and double combined) and vaginal prostaglandins have comparable cesarean delivery rates and maternal safety profiles, but balloon catheters lead to fewer adverse perinatal events 27 . Therefore, balloon catheters should be used more widely in labor induction.…”
Section: Discussionmentioning
confidence: 99%
“…We recently demonstrated in another IPD‐MA that balloon catheters (single and double combined) and vaginal prostaglandins have comparable cesarean delivery rates and maternal safety profiles, but balloon catheters lead to fewer adverse perinatal events. 27 Therefore, balloon catheters should be used more widely in labor induction. Considering the findings of this study and the associated costs of interventions, single‐balloon catheter is a better option in the induction of labor, especially in low‐resource settings.…”
Section: Discussionmentioning
confidence: 99%
“…First of all, we cannot deny the small size of the cases in this study. In this study, we could not examine the incidence of uterine tachysystole associated with excessive uterine activity, which is a possible adverse event of prostaglandin E2 (PGE2) preparations [ 14 , 15 ]. However, there were not any cases of these complications associated with the small sample size in this study.…”
Section: Discussionmentioning
confidence: 99%
“…Finally, the use of oral misoprostol was associated with a lower risk of caesarean section. However, a meta-analysis recently published this November (22) administration, the dose could be repeated or oxytocin could be started (23).…”
Section: Discussionmentioning
confidence: 99%