Ballistocardiography Can Estimate Beat-to-Beat Heart Rate Accurately at Night in Patients After Vascular Intervention

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 16 publications
0
12
0
Order By: Relevance
“…Therefore, research on anti-interference algorithm is the key to improve the accuracy of BCG analysis. For example, Antink et al [19] used a continuous local interval estimator (CLIE) approach to estimate the beat-to-beat intervals (BBIs). To reduce the influence of frequent motion artifacts on the analysis results, the CLIE method used ultrashort-term HRV analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, research on anti-interference algorithm is the key to improve the accuracy of BCG analysis. For example, Antink et al [19] used a continuous local interval estimator (CLIE) approach to estimate the beat-to-beat intervals (BBIs). To reduce the influence of frequent motion artifacts on the analysis results, the CLIE method used ultrashort-term HRV analysis.…”
Section: Introductionmentioning
confidence: 99%
“…The need for simple, low-cost and non-invasive methods to monitor the cardiovascular system has encouraged the development of PW systems as an alternative to ECG [ 14 , 15 , 44 ]. In recent years, this need has also led to the re-emergence of BCG acquisition systems [ 45 , 46 , 47 , 48 ]. However, ECG and PW systems currently require that the sensors are either applied manually to the patient’s skin or, for longer-term use, are held in position with an adhesive patch, a strap or a more elaborate mechanical device such as the one used in this study for PW measurements.…”
Section: Discussionmentioning
confidence: 99%
“…To quantify the performance of the proposed sensor mat for HR and BR estimates compared with the reference ECG signal and effort belt signal, the Bland-Altman plot, Pearson correlation coefficient, normalized root mean square error (NRMSE), normalized mean absolute error (NMAE), and mean absolute percentage error (MAPE) were adopted. These metrics are commonly employed to determine the difference between medical instruments [ 44 - 48 ]. Further information about these error metrics can be found in Multimedia Appendix 1 .…”
Section: Methodsmentioning
confidence: 99%