Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background Modern ballistocardiography (BCG) and seismocardiography (SCG) use acceleration sensors to measure oscillating recoil movements of the body caused by the heartbeat and blood flow, which are transmitted to the body surface. Acceleration artifacts occur through intrinsic sensor roll, pitch, and yaw movements, assessed by the angular velocities of the respective sensor, during measurements that bias the signal interpretation. Objective This observational study aims to generate hypotheses on the detection and elimination of acceleration artifacts due to the intrinsic rotation of accelerometers and their differentiation from heart-induced sensor accelerations. Methods Multimodal data from 4 healthy participants (3 male and 1 female) using BCG-SCG and an electrocardiogram will be collected and serve as a basis for signal characterization, model modulation, and location vector derivation under parabolic flight conditions from µg to 1.8g. The data will be obtained during a parabolic flight campaign (3 times 30 parabolas) between September 24 and July 25 (depending on the flight schedule). To detect the described acceleration artifacts, accelerometers and gyroscopes (6-degree-of-freedom sensors) will be used for measuring acceleration and angular velocities attributed to intrinsic sensor rotation. Changes in acceleration and angular velocities will be explored by conducting descriptive data analysis of resting participants sitting upright in varying gravitational states. Results A multimodal data set will serve as a basis for research into a noninvasive and gentle method of BCG-SCG with the aid of low-noise and synchronous 3D gyroscopes and 3D acceleration sensors. Hypotheses will be generated related to detecting and eliminating acceleration artifacts due to the intrinsic rotation of accelerometers and gyroscopes (6-degree-of-freedom sensors) and their differentiation from heart-induced sensor accelerations. Data will be collected entirely and exclusively during the parabolic flights, taking place between September 2024 and July 2025. Thus, as of June 2024, no data have been collected yet. The data will be analyzed until December 2025. The results are expected to be published by June 2026. Conclusions The study will contribute to understanding artificial acceleration bias to signal readings. It will be a first approach for a detection and elimination method. Trial Registration Deutsches Register Klinische Studien DRKS00034402; https://drks.de/search/en/trial/DRKS00034402 International Registered Report Identifier (IRRID) PRR1-10.2196/63306
Background Modern ballistocardiography (BCG) and seismocardiography (SCG) use acceleration sensors to measure oscillating recoil movements of the body caused by the heartbeat and blood flow, which are transmitted to the body surface. Acceleration artifacts occur through intrinsic sensor roll, pitch, and yaw movements, assessed by the angular velocities of the respective sensor, during measurements that bias the signal interpretation. Objective This observational study aims to generate hypotheses on the detection and elimination of acceleration artifacts due to the intrinsic rotation of accelerometers and their differentiation from heart-induced sensor accelerations. Methods Multimodal data from 4 healthy participants (3 male and 1 female) using BCG-SCG and an electrocardiogram will be collected and serve as a basis for signal characterization, model modulation, and location vector derivation under parabolic flight conditions from µg to 1.8g. The data will be obtained during a parabolic flight campaign (3 times 30 parabolas) between September 24 and July 25 (depending on the flight schedule). To detect the described acceleration artifacts, accelerometers and gyroscopes (6-degree-of-freedom sensors) will be used for measuring acceleration and angular velocities attributed to intrinsic sensor rotation. Changes in acceleration and angular velocities will be explored by conducting descriptive data analysis of resting participants sitting upright in varying gravitational states. Results A multimodal data set will serve as a basis for research into a noninvasive and gentle method of BCG-SCG with the aid of low-noise and synchronous 3D gyroscopes and 3D acceleration sensors. Hypotheses will be generated related to detecting and eliminating acceleration artifacts due to the intrinsic rotation of accelerometers and gyroscopes (6-degree-of-freedom sensors) and their differentiation from heart-induced sensor accelerations. Data will be collected entirely and exclusively during the parabolic flights, taking place between September 2024 and July 2025. Thus, as of June 2024, no data have been collected yet. The data will be analyzed until December 2025. The results are expected to be published by June 2026. Conclusions The study will contribute to understanding artificial acceleration bias to signal readings. It will be a first approach for a detection and elimination method. Trial Registration Deutsches Register Klinische Studien DRKS00034402; https://drks.de/search/en/trial/DRKS00034402 International Registered Report Identifier (IRRID) PRR1-10.2196/63306
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.