2017
DOI: 10.1039/c7nr01530e
|View full text |Cite
|
Sign up to set email alerts
|

Bacterial magnetosomes – nature's powerful contribution to MPI tracer research

Abstract: The magnetic particle spectrum (MPS) of bacterial magnetosomes, isolated from Magnetospirillum gryphiswaldense, is measured and compared to that of the current "gold standard", Resovist®. It is shown that the amplitudes of the magnetosomes' harmonics by far exceed that of Resovist®; the amplitude of the third harmonic is higher by a factor of 7, and is the highest value obtained for iron oxide nanoparticles to date.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
45
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(45 citation statements)
references
References 27 publications
0
45
0
Order By: Relevance
“…The highly squared AC hysteresis loops measured for the aligned bacteria (see Figure ) present a high harmonic distortion on odd harmonics (3rd, 5th, 7th, …), thus making these magnetotactic bacteria very promising candidates for MPI. The suitability of isolated bacterial magnetosomes as MPI tracer has already been reported in the literature …”
Section: Resultsmentioning
confidence: 68%
See 1 more Smart Citation
“…The highly squared AC hysteresis loops measured for the aligned bacteria (see Figure ) present a high harmonic distortion on odd harmonics (3rd, 5th, 7th, …), thus making these magnetotactic bacteria very promising candidates for MPI. The suitability of isolated bacterial magnetosomes as MPI tracer has already been reported in the literature …”
Section: Resultsmentioning
confidence: 68%
“…The suitability of isolated bacterial magnetosomes as MPI tracer has already been reported in the literature. [59]…”
Section: Magnetic Hyperthermiamentioning
confidence: 99%
“…Recently, Kraupner and colleagues [ 118 ] compared the use of magnetosomes as a magnetic tracer material in a new diagnostic imaging technology called magnetic particle imaging (MPI), to the use of the gold standard commercial tracer Resovist ® . Results showed a significant increase in particle detection and, consequently, improvement in the resolution of the technique when magnetosomes were applied [ 118 ].…”
Section: Resultsmentioning
confidence: 99%
“…11 In a previous study, magnetosome contrast enhancement was determined to be slightly elevated compared to the former iron oxide-based "gold-standard", Resovist, with a hydrodynamic diameter between 45 and 60 nm and an iron oxide nanoparticle core between only 5 and 6 nm. 11,31 We measured an increased reduction of T2-weighted signal relaxation time of 17.3±2.6 ms for purified magnetosomes with an iron oxide core diameter of approximately 40 nm at an iron concentration of 0.2 mM. This effect on T2 relaxation time reduction exceeded that of commercial, well dispersed magnetite particles with a similar core diameter of 25 nm, for which a value of 31.9±2.6 ms was measured at the same iron concentration ( Fig.…”
Section: Purified Magnetosomes Are Suitable T2-relaxation Contrast Agmentioning
confidence: 99%