2002
DOI: 10.1097/00003086-200211000-00004
|View full text |Cite
|
Sign up to set email alerts
|

Backsurface Wear and Deformation in Polyethylene Tibial Inserts Retrieved Postmortem

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
20
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 39 publications
(23 citation statements)
references
References 15 publications
3
20
0
Order By: Relevance
“…Backside wear retrieval studies of tibial components have reported burnishing, pitting, and polyethylene protrusion into the tray's screw holes (Conditt et al, 2004b;Cuckler et al, 2003;Engh et al, 2001;Parks et al, 1998;Rao et al, 2002;Surace et al, 2002). Our findings are consistent with this in that burnishing was the prevalent mode of polyethylene damage, especially when fretted against rougher surfaces.…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…Backside wear retrieval studies of tibial components have reported burnishing, pitting, and polyethylene protrusion into the tray's screw holes (Conditt et al, 2004b;Cuckler et al, 2003;Engh et al, 2001;Parks et al, 1998;Rao et al, 2002;Surace et al, 2002). Our findings are consistent with this in that burnishing was the prevalent mode of polyethylene damage, especially when fretted against rougher surfaces.…”
Section: Discussionsupporting
confidence: 87%
“…However, the relative influences of metal surface roughness, alloy, and micromotion on fretting wear have not been systematically studied. Rather, most studies have used retrieved implants, scoring damage on the inferior surface (Engh et al, 2001;Harman et al, 2007;Rao et al, 2002;Surace et al, 2002;Wasielewski et al, 1997), measuring polyethylene extrusion from inferior insert surfaces into tibial tray screw holes (Conditt et al, 2005), or measuring decreases in depths of manufacturer's stamped markings on the inferior polyethylene surface (Crowninshield et al, 2006). Although these studies provide valuable information, they are indirect retrospective measurements.…”
Section: Introductionmentioning
confidence: 99%
“…Despite the fact that the neocapsule is not responsible for loosening, it can give useful diagnostic information. Several studies have shown that the new joint space interacts with the periprosthetic space, [21][22][23] and it is generally accepted that the changes in histological appearance are very similar in these different tissue specimens in the same patient. 13 17 The periprosthetic membrane is marked by a heterogeneous appearance in histopathology.…”
mentioning
confidence: 99%
“…Analysis of backside wear of tibial inserts suggested that the majority of wear from knee implants comes from the backside. 16,24 Storing the retrieved implants provides an invaluable resource for research and analysis. In a recent study, the records of 26 patients (27 knees) who sustained a fracture of a total condylar design total knee prosthesis revealed 25 fractures involving the tibial component and two fractures involving the femoral component.…”
Section: Discussionmentioning
confidence: 99%