2009
DOI: 10.1016/j.humimm.2009.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Back to the future: application of contemporary technology to long-standing questions about the clinical relevance of human leukocyte antigen-specific alloantibodies in renal transplantation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
55
0
1

Year Published

2012
2012
2018
2018

Publication Types

Select...
6
2
2

Relationship

0
10

Authors

Journals

citations
Cited by 67 publications
(59 citation statements)
references
References 43 publications
3
55
0
1
Order By: Relevance
“…As shown in Figure 8, the antibodies against A2, A69, B51, and B52 exhibited oversaturation that disappeared upon the dilution of the serum. This prozoning effect has been reported by others with the SA Luminex bead assay [119][120][121][122][123] . Dilution of the serum to exclude the oversaturation of antibodies is critical when the antibody analysis is performed on the sera of highly sensitized TCs who have been subjected to immunomodulation/desensitization.…”
Section: Bead Oversaturationsupporting
confidence: 81%
“…As shown in Figure 8, the antibodies against A2, A69, B51, and B52 exhibited oversaturation that disappeared upon the dilution of the serum. This prozoning effect has been reported by others with the SA Luminex bead assay [119][120][121][122][123] . Dilution of the serum to exclude the oversaturation of antibodies is critical when the antibody analysis is performed on the sera of highly sensitized TCs who have been subjected to immunomodulation/desensitization.…”
Section: Bead Oversaturationsupporting
confidence: 81%
“…This fact may contribute to the controversy on the clinical relevance of HLAab as there is an eminent discrepancy in antigen density between the antibody detection assay and the surface of endothelial cells as the antibody target of a renal allograft. Consequently, HLA-DQ antibodies detected exclusively by SAB reveal only a low immunological risk for renal transplant [21]. Disparities in relative antigen quantity exist not only across different bead formats but also among SAB.…”
Section: Principles Of the Luminex Methodsmentioning
confidence: 99%
“…Pretransplant antibody screening was performed using a dithiothreitol (DTT)-modified complement-dependent cytotoxicity (CDC) assay, as described previously (10). Antibody characterization was undertaken using HLA class I and class II single-antigen HLA-specific antibody detection beads (LABScreen R ; One Lambda Inc., Canoga Park, CA, USA).…”
Section: Casementioning
confidence: 99%