2013
DOI: 10.1016/j.ajic.2013.03.293
|View full text |Cite
|
Sign up to set email alerts
|

B95: A new respirator for health care personnel

Abstract: This article summarizes the outputs of the Project BREATHE Working Group and provides a national strategy to develop clinically validated respirator test methods, to promulgate B95 respirator standards, and to invent novel design features, which together will lead to commercialized B95 respirators.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
83
0
3

Year Published

2014
2014
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 60 publications
(86 citation statements)
references
References 30 publications
(28 reference statements)
0
83
0
3
Order By: Relevance
“…Data for the current study were drawn from subjects in two separate Project BREATHE [11] reports (investigations a (not published) and b [12]) totaling 67 individuals. Investigation a subject demographic mean values (SD) for men (n = 12) were age 22.6 years (2.7), height 180.8 cm (7.9), weight 84.1 kg (16.5) and Body Mass Index (BMI) 25.7 kg/m 2 (4.8), and for women (n = 9) were age 23.7 years (3.3), height 166.4 cm (4.0), weight 65.6 kg (6.5) and BMI 23.7 kg/m 2 (2.6).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Data for the current study were drawn from subjects in two separate Project BREATHE [11] reports (investigations a (not published) and b [12]) totaling 67 individuals. Investigation a subject demographic mean values (SD) for men (n = 12) were age 22.6 years (2.7), height 180.8 cm (7.9), weight 84.1 kg (16.5) and Body Mass Index (BMI) 25.7 kg/m 2 (4.8), and for women (n = 9) were age 23.7 years (3.3), height 166.4 cm (4.0), weight 65.6 kg (6.5) and BMI 23.7 kg/m 2 (2.6).…”
Section: Methodsmentioning
confidence: 99%
“…The N95 class of FFR (N95 FFR) is the most commonly used respirator in U.S. healthcare [9], but limited scientific data is available about its impact on TMT [10]. This investigation is part of the National Institute for Occupational Safety and Health’s (NIOSH) Project BREATHE (Better Respiratory Equipment using Advanced Technologies for Healthcare Employees), which is addressing respiratory protection needs of healthcare workers [11] and some of the results of which have previously been published [12, 13]. The current study was undertaken to assess the impact of wearing N95 FFRs on infrared TMT measurements.…”
Section: Introductionmentioning
confidence: 99%
“…Project BREATHE seeks to develop respirator test methods, respirator standards for a “B95” 1 respirator class, and invent novel design features, which together will lead to commercial products that are more comfortable and useable for HCWs (18) . Although a priority within Project BREATHE, the state of test methods for occupational interference (which includes SI) was recently deemed not practical for inclusion in a draft B95 standard (19) .…”
Section: Introductionmentioning
confidence: 99%
“…Part of that effort includes development of the B95 standard, which would include testing for comfort. 38 The development of standardized test methods assessing comfort and usability will likely spur additional research in this area, leading to increased publications for future trend analysis.…”
Section: Discussionmentioning
confidence: 99%