B0 shimming for in vivo magnetic resonance spectroscopy: Experts' consensus recommendations

Abstract: Magnetic resonance spectroscopy (MRS) and spectroscopic imaging (MRSI) allow the chemical analysis of physiological processes in vivo and provide powerful tools in the life sciences and for clinical diagnostics. Excellent homogeneity of the static B 0 magnetic field over the object of interest is essential for achieving high-quality spectral results and quantitative metabolic measurements. The experimental minimization of B 0 variation is performed in a process called B 0 shimming. In this article, we summariz… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
102
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
10

Relationship

4
6

Authors

Journals

citations
Cited by 72 publications
(117 citation statements)
references
References 87 publications
(99 reference statements)
0
102
0
Order By: Relevance
“…In order to reliably image gliomas in the basal parts of the brain, significant improvements in B 0 shim hardware is warranted to improve B 0 homogeneity throughout the brain ( Juchem et al, 2020 , Wilson et al, 2019 ). Together with motion correction, this will improve the robustness of 7T MRSI, particularly when whole-brain coverage is required ( Maudsley et al, 2020 ).…”
Section: Discussionmentioning
confidence: 99%
“…In order to reliably image gliomas in the basal parts of the brain, significant improvements in B 0 shim hardware is warranted to improve B 0 homogeneity throughout the brain ( Juchem et al, 2020 , Wilson et al, 2019 ). Together with motion correction, this will improve the robustness of 7T MRSI, particularly when whole-brain coverage is required ( Maudsley et al, 2020 ).…”
Section: Discussionmentioning
confidence: 99%
“…g. Shimming method, 10 reference peak used for assessing shim performance, and thresholds for "acceptance of shim" chosen.…”
Section: Reporting Guidelinesmentioning
confidence: 99%
“…2 However, the line broadening resulting from microscopic ΔB 0 increases linearly with B 0. 2,43 Even though the ΔB 0 , macro component can be substantially minimized by successful B 0 shimming, 45 the ΔB 0 , micro component cannot be eliminated as it originates from intrinsic tissue heterogeneity on a cellular level. Therefore, the effect of ΔB 0 , micro line broadening should be identical for metabolites and MM.…”
Section: Recommendations On Nomenclaturementioning