2020
DOI: 10.1002/mp.14306
|View full text |Cite
|
Sign up to set email alerts
|

B0 field homogeneity recommendations, specifications, and measurement units for MRI in radiation therapy

Abstract: Purpose: The purpose is: (a) Relate magnetic resonance imaging (MRI) quality recommendations for radiation therapy (RT) to B 0 field homogeneity; (b) Evaluate manufacturer specifications of B 0 homogeneity for 34 commercial whole-body MRI systems based on the MRI quality recommendations and RT application; (c) Measure field homogeneity in five commercial MRI systems and one commercial MRI-Linac used in RT and compare the results with their B 0 homogeneity specifications. Methods: Magnetic resonance imaging qua… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(27 citation statements)
references
References 62 publications
0
26
1
Order By: Relevance
“…In addition, the tool uses a fixed, phantom‐based shim (“Tune Up” shim mode) based on the field homogeneity at 0 ° . The measurement may fail from strong spin dephasing if used at gantry angles other than 0° since there are variations in field homogeneity with gantry angle and the tool does not reshim the magnetic field prior to the measurement of eddy currents 12 . The tool also requires and verifies phantom position offsets of ≤5 mm for X and Y axes, and ≤3 mm for the Z axis before acquiring eddy current measurements.…”
Section: Methodsmentioning
confidence: 99%
“…In addition, the tool uses a fixed, phantom‐based shim (“Tune Up” shim mode) based on the field homogeneity at 0 ° . The measurement may fail from strong spin dephasing if used at gantry angles other than 0° since there are variations in field homogeneity with gantry angle and the tool does not reshim the magnetic field prior to the measurement of eddy currents 12 . The tool also requires and verifies phantom position offsets of ≤5 mm for X and Y axes, and ≤3 mm for the Z axis before acquiring eddy current measurements.…”
Section: Methodsmentioning
confidence: 99%
“…This value shall also be within the vendor specification that may be defined across a certain DSV. A comprehensive report has outlined B 0 homogeneity specifications across a 40 cm DSV ranging from 0.35 to 5 ppm (median = 0.75 ppm) VRMS for 1.5 T systems and 0.2 to 1.4 ppm (median = 0.5 ppm) VRMS for 3 T systems 63 . Detailed methods for measuring MFH are outlined in several other reports 57,63 .…”
Section: Accepted Articlementioning
confidence: 99%
“…Since measured and expected field distortions are compared between systems (with different machine-related B0 inhomogeneities) this workflow unjustly incorporates machine-related field distortions measured on the MRsim into the expected geometric distortions on the MR-linac. This effect, however, is expected to be negligible as field inhomogeneities are typically ≲1 ppm inside a sphere with a diameter of 40 cm for most clinical MR systems [29] .…”
Section: Discussionmentioning
confidence: 99%