2011
DOI: 10.1016/j.cemconcomp.2011.03.011
|View full text |Cite
|
Sign up to set email alerts
|

Axial capacity of post-heated square columns wrapped with FRP composites

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 55 publications
(23 citation statements)
references
References 22 publications
0
23
0
Order By: Relevance
“…For the normal condition of concrete, calcium hydroxide, Ca(OH) 2 , is created in the hydration process of cement, which is described by…”
Section: Neutralization Test Of Concretementioning
confidence: 99%
See 1 more Smart Citation
“…For the normal condition of concrete, calcium hydroxide, Ca(OH) 2 , is created in the hydration process of cement, which is described by…”
Section: Neutralization Test Of Concretementioning
confidence: 99%
“…Furthermore, a reinforced concrete (RC) structure with proper reinforcement details can effectively redistribute loads from damaged region to undamaged components even if the part of the structure is severely damaged by fire. Therefore, it is not common for fire-damaged RC structures to completely collapse during or after an event of fire [2].…”
Section: Introductionmentioning
confidence: 99%
“…As such, the numerous applications of FRP composites in repairing reinforced concrete (RC) structural elements have been widely investigated over the past three decades. Very few experimental investigations have recently examined the potential of using FRP composites to repair heatdamaged RC columns Bailey 2011a, b, 2012;Yaqub et al 2011Bisby et al 2011;Bailey and Yaqub 2012;Tahir et al 2013;Al-Nimry et al 2013;Roy et al 2014Roy et al , 2016Al-Kamaki et al 2015). Most of the test columns were unstressed during heating, cooling and testing despite the fact that columns are expected to be stressed up to 50% of their capacity during any fire incident.…”
Section: Introductionmentioning
confidence: 99%
“…To this end, Al-Kamaki et al (2015) applied an axial compressive loading of 30% of the maximum compressive strength at ambient temperature while exposing the test columns to elevated temperatures. Available research results Bailey 2011a, b, 2012;Yaqub et al 2011Bisby et al 2011;Bailey and Yaqub 2012;Tahir et al 2013;Al-Nimry et al 2013;Roy et al 2014Roy et al , 2016Al-Kamaki et al 2015) indicated that jacketing heat-damaged columns with unidirectional FRP sheets may, depending on the cross sectional shape, restore the axial strength of the columns. FRP jacketing has been found efficient in enhancing the ductility, deformation and energy dissipation capacities of heat-damaged columns.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation