2022
DOI: 10.1016/j.jacep.2022.04.017
|View full text |Cite
|
Sign up to set email alerts
|

Autonomic Changes Are More Durable After Radiofrequency Than Pulsed Electric Field Pulmonary Vein Ablation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 28 publications
0
11
0
Order By: Relevance
“…Complications from the esophageal cooling device itself have been infrequent, with most occurring during long-term use for critical care patients (where durations of use extend well beyond 24 hours). [52][53][54] New technologies may arrive that further reduce the risk of AEF, such as irreversible electroporation, or pulsed field ablation (PFA); however concerns remain about both the longterm efficacy of procedures utilizing PFA, [55,56] as well as growing awareness of risks emerging with PFA, including stroke, acute coronary artery spasm, and delayed arterial injury via neointimal hyperplasia and medial fibrosis resulting in arterial stenosis. [57][58][59] Moreover, reports of fistula formation after irreversible electroporation are abundant in the oncology literature, which raises the question of whether PFA can actually eliminate the risk of AEF.…”
Section: Discussionmentioning
confidence: 99%
“…Complications from the esophageal cooling device itself have been infrequent, with most occurring during long-term use for critical care patients (where durations of use extend well beyond 24 hours). [52][53][54] New technologies may arrive that further reduce the risk of AEF, such as irreversible electroporation, or pulsed field ablation (PFA); however concerns remain about both the longterm efficacy of procedures utilizing PFA, [55,56] as well as growing awareness of risks emerging with PFA, including stroke, acute coronary artery spasm, and delayed arterial injury via neointimal hyperplasia and medial fibrosis resulting in arterial stenosis. [57][58][59] Moreover, reports of fistula formation after irreversible electroporation are abundant in the oncology literature, which raises the question of whether PFA can actually eliminate the risk of AEF.…”
Section: Discussionmentioning
confidence: 99%
“…A similar temporary influence of PFA on the GP has been observed also with a different PFA technology. Stojadinovic et al 14 reported a reduced response of both the sinoatrial and the atrioventricular node to ECVS after PVI with PFA with the Affera system (Affera; Medtronic). However, the effects on the ANS induced by this PFA technology were still present 20 min after ablation in ∼30% of patients.…”
Section: Discussionmentioning
confidence: 99%
“…31 One case of successful termination of an AT from the right atrial appendage by PFA after failed RFA has been published. 32…”
Section: Beyond Pulmonary Vein Isolationmentioning
confidence: 99%