1961
DOI: 10.1021/ac60171a018
|View full text |Cite
|
Sign up to set email alerts
|

Automation of Ion Exchange Chromatographic Analysis of Condensed Phosphate Mixtures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

1963
1963
1998
1998

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…Early methods for the analysis of STP were based on the separation of phosphate species using an ionexchange column, followed by acid hydrolysis of the STP to orthophosphate, which was then determined colorimetrically as a molybdenum blue complex (Lindenbaum et al 1954;Grande & Beukamp 1956;Lundgren & Loeb 1961). Most of these workers were involved in the analysis of fairly high concentrations of STP.…”
Section: Detection Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Early methods for the analysis of STP were based on the separation of phosphate species using an ionexchange column, followed by acid hydrolysis of the STP to orthophosphate, which was then determined colorimetrically as a molybdenum blue complex (Lindenbaum et al 1954;Grande & Beukamp 1956;Lundgren & Loeb 1961). Most of these workers were involved in the analysis of fairly high concentrations of STP.…”
Section: Detection Methodsmentioning
confidence: 99%
“…Most of these workers were involved in the analysis of fairly high concentrations of STP. Lundgren & Loeb (1961) suggested that STP may spontaneously degrade below 4 g m 3 . However, Morita & Uehiro (1981) used high pressure liquid chromatography (HPLC) to analyse STP to low levels, and provided figures which suggest a concentration detection limit of c. 0.3 g nT 3 .…”
Section: Detection Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The technique has been used in the analysis and study of. among others, thin-layer chromatography plates ( I ) ; semiconductor materials ( 2 ) ; low magnitude optical absorption coefficients (3)(4)(5); thermal diffusivity constants (6); fluorescence in solids (7)(8)(9); radiationless transitions ( 1 0 , I I ) ; qualitative identification of uranium tetrafluoride (12); biological systems (13)(14)(15)(16); and excited states of a solid (17).…”
Section: Harry E Eaton" and James D Stuartmentioning
confidence: 99%
“…The STP method of Lundgren & Loeb (1961) was modified to give lower detection levels. The STP autoanalyser manifold design is shown in Fig.…”
Section: Methodsmentioning
confidence: 99%