2020
DOI: 10.1007/978-3-030-58362-0_20
|View full text |Cite
|
Sign up to set email alerts
|

Automation of Cup Filling Machine by Inserting PLC Control Unit for Educational Purpose

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 4 publications
0
3
0
Order By: Relevance
“…Since the pump is at the same level as the nozzle, there is no need to compensate for the gravity. Filling times for both cup sizes/ volumes, either V1 = 0.1 l or V2 = 0.2 l, are calculated by the following equations, (1) and (2).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Since the pump is at the same level as the nozzle, there is no need to compensate for the gravity. Filling times for both cup sizes/ volumes, either V1 = 0.1 l or V2 = 0.2 l, are calculated by the following equations, (1) and (2).…”
Section: Methodsmentioning
confidence: 99%
“…Finally, the machine is tested and put into use. It was determined empirically (references in [2]) that 19 s is enough to fill the cup of 0.2 l and not to overspill it. Smaller cups are sorted to one side and larger ones to another side.…”