2021
DOI: 10.1371/journal.pone.0248264
|View full text |Cite
|
Sign up to set email alerts
|

Automatic real-time analysis and interpretation of arterial blood gas sample for Point-of-care testing: Clinical validation

Abstract: Background Point-of-care arterial blood gas (ABG) is a blood measurement test and a useful diagnostic tool that assists with treatment and therefore improves clinical outcomes. However, numerically reported test results make rapid interpretation difficult or open to interpretation. The arterial blood gas algorithm (ABG-a) is a new digital diagnostics solution that can provide clinicians with real-time interpretation of preliminary data on safety features, oxygenation, acid-base disturbances and renal profile. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 16 publications
1
6
0
Order By: Relevance
“…Furthermore, a significant relationship was found between the quantitative pH and the degree of cardiac function, this finding is common with previous experimental studies where a progressive fall in pH during acid infusion in experimental models is associated with a decrease in cardiac output. These data support the potential value of a early detection of acidemia [ 33 , 34 ] and the possible benefit of improving arterial pH in these patients.…”
Section: Discussionsupporting
confidence: 77%
“…Furthermore, a significant relationship was found between the quantitative pH and the degree of cardiac function, this finding is common with previous experimental studies where a progressive fall in pH during acid infusion in experimental models is associated with a decrease in cardiac output. These data support the potential value of a early detection of acidemia [ 33 , 34 ] and the possible benefit of improving arterial pH in these patients.…”
Section: Discussionsupporting
confidence: 77%
“…The disorder of electrolytes can be considered one of the most pressing medical issues in the ICU and other hospitalized patients. It has been reported that electrolyte imbalances are associated with increased morbidity and mortality among ill patients [ 2 ].…”
Section: Introductionmentioning
confidence: 99%
“…This technological feature can make understanding and interpretation of blood gases faster and easier. Use of ABG-a could help healthcare professionals to improve workflow and even patient safety by reducing potential human errors at overwhelmed ICUs with limited personal and equipment resources [ 37 ].…”
Section: Point-of-care Diagnostics In Haematology and Biochemistrymentioning