2014
DOI: 10.6113/jpe.2014.14.4.742
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Power Factor Correction Using a Harmonic-Suppressed TCR Equipped with a New Adaptive Current Controller

Abstract: In this paper, a new continuously and linearly controlled capacitive static VAR compensator is proposed for the automatic power factor correction of inductive single phase loads in 220V 50Hz power system networks. The compensator is constructed of a harmonic-suppressed TCR equipped with a new adaptive current controller. The harmonic-suppressed TCR is a new configuration that includes a thyristor controlled reactor (TCR) shunted by a passive third harmonic filter. In addition, the parallel configuration is con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
1
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 30 publications
0
1
0
Order By: Relevance
“…Figure 3a shows a TCR supplied directly from an AC voltage vAC and fired at an angle α as shown in Figure 3b. According to this firing angle, the TCR fundamental current component I1 can be given by [6][7][8][9]:…”
Section: Figure 2 the Power Circuit Of The Proposed Susceptancementioning
confidence: 99%
See 1 more Smart Citation
“…Figure 3a shows a TCR supplied directly from an AC voltage vAC and fired at an angle α as shown in Figure 3b. According to this firing angle, the TCR fundamental current component I1 can be given by [6][7][8][9]:…”
Section: Figure 2 the Power Circuit Of The Proposed Susceptancementioning
confidence: 99%
“…A TCR equipped with a new adaptive current controller and specific filtering circuits was proposed to automatically correct the power factor of an inductive load, eliminating harmonic injection on the AC source side [9]. The optimal design of new topologies of TSRs was suggested [10] to achieve uniformly distributed Var control in power system networks.…”
Section: Introductionmentioning
confidence: 99%
“…where, AM is the analogue multiplier gain and Vm is vAC amplitude. The output vS of the summing amplifier is defined by (13).…”
Section: The Statcom Current Controllermentioning
confidence: 99%
“…Using phase shift SPWM, two control loops (phase angle and DC voltage) were exploited to certify the balance of the DC voltages and to calculate parameters of the PI controller. A harmonic free TCR was introduced in [12] as a compensating susceptance controlled linearly and continuously in inductive operational mode, whereas in [13] a TCR equipped with a new current controller and an adaptive filtering scheme was introduced to function as a continuously and linearly controlled capacitive susceptance. Both categories were dedicated for power quality purposes like power factor correction and load balancing.…”
Section: Introductionmentioning
confidence: 99%
“…Today, power switching converters are widely used in many applications such as fuel cells [1], LED drivers [2], power factor correction [3] and photovoltaic systems [4]. Among the various switching converters, the flyback topology is widely used in electronic systems due to its benefits such as isolation and a simple structure.…”
Section: Introductionmentioning
confidence: 99%