2015
DOI: 10.2116/analsci.31.383
|View full text |Cite
|
Sign up to set email alerts
|

Automatic On-line Solid-phase Extraction-Electrothermal Atomic Absorption Spectrometry Exploiting Sequential Injection Analysis for Trace Vanadium, Cadmium and Lead Determination in Human Urine Samples

Abstract: A fully automated sequential injection column preconcentration method for the on-line determination of trace vanadium, cadmium and lead in urine samples was successfully developed, utilizing electrothermal atomic absorption spectrometry (ETAAS). Polyamino-polycarboxylic acid chelating resin (Nobias chelate PA-1) packed into a handmade minicolumn was used as a sorbent material. Effective on-line retention of chelate complexes of analytes was achieved at pH 6.0, while the highest elution effectiveness was observ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(2 citation statements)
references
References 41 publications
0
2
0
Order By: Relevance
“…This can be explained both by the use of high-purity reagents that are available for the proposed procedure and by the specific properties of the resin used. Nobias shows extremely low affinity towards alkaline metals [ 17 ] combined with almost quantitative sorption of transition metals in pH 5–6 [ 18 ] while the affinity is decreased significantly in pH < 4 [ 19 , 20 ]. REE metals show quantitative sorption in a similar pH range to the transition metals [ 21 ] but extend this property to more acidic conditions: pH 4.2 was successfully reported [ 13 ] and even pH 2.5 is suitable for efficient sorption [ 22 ], which is consistent for scandium in the present results ( Figure 1 ).…”
Section: Resultsmentioning
confidence: 99%
“…This can be explained both by the use of high-purity reagents that are available for the proposed procedure and by the specific properties of the resin used. Nobias shows extremely low affinity towards alkaline metals [ 17 ] combined with almost quantitative sorption of transition metals in pH 5–6 [ 18 ] while the affinity is decreased significantly in pH < 4 [ 19 , 20 ]. REE metals show quantitative sorption in a similar pH range to the transition metals [ 21 ] but extend this property to more acidic conditions: pH 4.2 was successfully reported [ 13 ] and even pH 2.5 is suitable for efficient sorption [ 22 ], which is consistent for scandium in the present results ( Figure 1 ).…”
Section: Resultsmentioning
confidence: 99%
“…A number of papers were published describing online enhancement options for ETAAS such as pre-concentration and speciation. A rapid, online SPE system coupled to ETAAS was proposed by Giakisikli and co-workers 59 for the determination of Cd, Pb and V in human urine. A mini-column packed with polyamino-polycarboxylic acid chelating resin was used to preconcentrate the analytes online.…”
Section: Atomic Absorption Spectrometrymentioning
confidence: 99%