2020
DOI: 10.1007/s11548-020-02226-8
|View full text |Cite
|
Sign up to set email alerts
|

Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
21
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(22 citation statements)
references
References 34 publications
1
21
0
Order By: Relevance
“…It showed that the accuracy of imaging was improved by this algorithm and the processing time was saved, which was beneficial for researchers to obtain objective and true imaging results in a short time. This is consistent with the result that Li et al applied the CNN model to the segmentation of prostate MRI images, which can shorten the labeling time and have a relatively high standard accuracy [ 21 ]. Magnetic resonance examination found that the lateral ventricles of the ventricles of some children were significantly enlarged, there were obvious perivascular spaces, accompanied by cribriform signs of deep white matter around the ventricles, hemangioma was faintly visible, and the abnormal signal foci were prominent.…”
Section: Discussionsupporting
confidence: 90%
“…It showed that the accuracy of imaging was improved by this algorithm and the processing time was saved, which was beneficial for researchers to obtain objective and true imaging results in a short time. This is consistent with the result that Li et al applied the CNN model to the segmentation of prostate MRI images, which can shorten the labeling time and have a relatively high standard accuracy [ 21 ]. Magnetic resonance examination found that the lateral ventricles of the ventricles of some children were significantly enlarged, there were obvious perivascular spaces, accompanied by cribriform signs of deep white matter around the ventricles, hemangioma was faintly visible, and the abnormal signal foci were prominent.…”
Section: Discussionsupporting
confidence: 90%
“…Reduced artifact levels should also improve the performance of needle tip detection using traditional and more recent deep-learning based image processing techniques. [54][55][56] For example, in Figure 5C, the orientation of the bevel becomes apparent after shimming, which could be further elucidated by image processing.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, the IoU level of auto-segmentation in this study was lower than that of auto-segmentation using MRI or ultrasonography in previous studies. [ 19 , 20 ] This is inevitable because the spatial resolution of fluoroscopy images is lower than that of MR or ultrasound images, which results in the lower contrast of the object in VFSS. In addition, we used the VFSS videoclips with 640 × 480 pixels in this study and, therefore, the boundaries of the structures in the VFSS frame were unclear.…”
Section: Discussionmentioning
confidence: 99%
“…Recent studies have used Mask R-CNN for automatic needle localization during ultrasound-guided prostate brachytherapy and automatic needle tracking during MRI-guided intervention. [ 18 , 19 ] A study used Mask R-CNN for automated thyroid nodule detection in ultrasonography. [ 20 ]…”
Section: Introductionmentioning
confidence: 99%