2016
DOI: 10.1038/srep37524
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Identification of Systolic Time Intervals in Seismocardiogram

Abstract: Continuous and non-invasive monitoring of hemodynamic parameters through unobtrusive wearable sensors can potentially aid in early detection of cardiac abnormalities, and provides a viable solution for long-term follow-up of patients with chronic cardiovascular diseases without disrupting the daily life activities. Electrocardiogram (ECG) and siesmocardiogram (SCG) signals can be readily acquired from light-weight electrodes and accelerometers respectively, which can be employed to derive systolic time interva… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
26
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(26 citation statements)
references
References 37 publications
0
26
0
Order By: Relevance
“…In a recent study, sophisticated in vivo experimental examinations and a complementary mathematical model revealed that BCG waves are formed due to blood pressure gradients in the ascending and descending aorta 17 . SCG and BCG, which are typically based on using accelerometers and force sensors, can be used for unobtrusive long term monitoring of LV to estimate hemodynamic variables, cardiac abnormalities, and breathing disorders via low-cost wearable or portable devices 1826 . Recent studies have also briefly described the feasibility of heart monitoring using built in accelerometer and gyroscope sensors in Google glasses, wrist worn devices, smart phones, and chest worn patches 27–30 .…”
Section: Introductionmentioning
confidence: 99%
“…In a recent study, sophisticated in vivo experimental examinations and a complementary mathematical model revealed that BCG waves are formed due to blood pressure gradients in the ascending and descending aorta 17 . SCG and BCG, which are typically based on using accelerometers and force sensors, can be used for unobtrusive long term monitoring of LV to estimate hemodynamic variables, cardiac abnormalities, and breathing disorders via low-cost wearable or portable devices 1826 . Recent studies have also briefly described the feasibility of heart monitoring using built in accelerometer and gyroscope sensors in Google glasses, wrist worn devices, smart phones, and chest worn patches 27–30 .…”
Section: Introductionmentioning
confidence: 99%
“…For example, by means of small MEMS (Micro Electro-Mechanical Systems) accelerometers attached to the chest wall, it is possible to record vibrations induced by cardiac activity: the study of such waveforms is the object of SCG. Indeed, analyses on SCG waveforms highlighted precise relations to specific events in the heart cycle [10]; SCG records traces of heart mechanical activity, which of course correlates to electrical activity inferred by standard ECG techniques: Figure 1 shows the temporal relation between ECG and SCG traces. SCG, in particular, allows for noticing many relevant events such as Mitral valve Opening (MO), and Closure (MC), Isovolumetric Moment (IM) contraction, Aortic valve Opening (AO) and Closure (AC).…”
Section: Introductionmentioning
confidence: 94%
“…Most research groups applied conventional band-pass filters to remove baseline wandering, body movements, and breathing artefacts from SCG signals [26,36,38,41,45,46,55,[58][59][60][61][62][63]67,71,75,76,[78][79][80]82,93]. A few studies utilized or proposed more advanced noise removal techniques [64,76,88,[94][95][96].…”
Section: Noise Reductionmentioning
confidence: 99%
“…More studies are needed that compare different filtering methods in clinical and ambulatory settings. [26,36,38,41,45,46,55,[58][59][60][61][62][63]67,71,75,76,[78][79][80]82,93] Adaptive filtering Motion artefact removal [88,95] Averaging theory Motion artefact removal [101] Comb filtering Removing respiration noise from radar signal [50] Empirical mode decomposition Baseline wandering, breathing and body movement artefact removal [76,94,95] Independent component analysis Motion artefact removal [102] Median filtering [96] Morphological filtering [95] Polynomial smoothing Motion artefact removal [103] Savitzky-Golay filtering Motion artefact removal [83,103] Wavelet denoising Segmentation of HSs and SCG [64,95,96] Wiener filtering [94] 2.…”
Section: Noise Reductionmentioning
confidence: 99%