2012 1st International Conference on Power and Energy in NERIST (ICPEN) 2012
DOI: 10.1109/icpen.2012.6492329
|View full text |Cite
|
Sign up to set email alerts
|

Automatic generation control of multi-area hydro system using classical controllers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…Different optimization methods are used in [171][172][173][174] for tuning the PID controllers' parameters of LFC. Authors in [183] presented the performances of different classical control approaches, e.g., proportional-integral (PI), integral plus double derivative (IDD), integral (I), and proportional-integral-derivative (PID), which are compared with recently introduced Proportional-Integral plus Double Derivative (PIDD) controllers for AGC [34].…”
Section: Classical Control Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Different optimization methods are used in [171][172][173][174] for tuning the PID controllers' parameters of LFC. Authors in [183] presented the performances of different classical control approaches, e.g., proportional-integral (PI), integral plus double derivative (IDD), integral (I), and proportional-integral-derivative (PID), which are compared with recently introduced Proportional-Integral plus Double Derivative (PIDD) controllers for AGC [34].…”
Section: Classical Control Methodsmentioning
confidence: 99%
“…An overview of LFC and AGC systems in two-area power systems is presented in [22][23][24][25][26][27][28][29][30][31][32][33][34][35][36][37][38][39][40]. Tie-lines models and their effects on LFC of two-area power systems are studied in [22,23].…”
Section: Dual-area Power Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…Evaluate the fitness of the population using fitness i = 1 1 + j 2 3. Using Equation (20), generate new NPs for the employed bees and evaluate the fitness 4. Apply the roulette wheel selection process to choose an NP 5.…”
Section: Artificial Bee Colony Optimization Algorithmmentioning
confidence: 99%
“…High voltage AC (HVAC) tie lines are used for interconnection in traditional power systems; the effects of HVAC tie line models were investigated in [14,15]. Studies for a two-area power system considering conventional multi-source plants were presented in [16][17][18][19][20] and higher-order interconnected areas were studied in [21][22][23][24][25][26]. The application of HVAC lines for long-distance transmission is associated with several drawbacks such as effect of capacitance for underground transmission [27], line inductance [28], Ferranti effect [29], asynchronous interconnection [30], and reduce active power transmission-to-length ratio [31].…”
Section: Introductionmentioning
confidence: 99%