2013
DOI: 10.1007/978-3-642-40760-4_47
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Detection of Multiple and Overlapping EP Catheters in Fluoroscopic Sequences

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 17 publications
0
17
0
Order By: Relevance
“…As a further pre-processing step, we use a determinant of hessian blob detector to obtain the accurate location of electrode-like structures appearing in the images. As demonstrated by [13,14], the electrodes can in this way be localized with submillimeter precision, therefore enabling us to effectively limit the search space.…”
Section: Pre-processingmentioning
confidence: 96%
See 1 more Smart Citation
“…As a further pre-processing step, we use a determinant of hessian blob detector to obtain the accurate location of electrode-like structures appearing in the images. As demonstrated by [13,14], the electrodes can in this way be localized with submillimeter precision, therefore enabling us to effectively limit the search space.…”
Section: Pre-processingmentioning
confidence: 96%
“…There, authors require user interaction for their detections using a geodesic framework. Finally, methods including fast blob detections, clustering, shape-constrained searching and catheter model-based detection have been proposed [13,14]. A limitation of these is that they assume fixed shape for the catheter and might not cope with different C-arm positions and catheter shape changes due to foreshortening.…”
Section: Introductionmentioning
confidence: 99%
“…Throughout the past years, there has been a lot of efforts towards detecting and tracking catheter tips in fluoroscopic sequences for various applications and purposes [12,14,15]. However, these techniques can not be applied for the stent graft delivery device due to its inhomogeneous appearance and rather large size.…”
Section: Related Workmentioning
confidence: 98%
“…Most of these tools are highly contrasted and relatively easy to segment. Milletari [13] showed that it's possible to segment EP catheters with segmentation accuracy of 99.3%. Brost et.…”
Section: Introductionmentioning
confidence: 99%
“…al [2] has also proposed efficient catheter tracking for electrophysiology procedures. Various works on segmentation of pigtail catheters [10] and EP catheters [12,13] portray the importance of segmentation of interventional tools and endovascular devices.…”
Section: Introductionmentioning
confidence: 99%