2015
DOI: 10.1109/lmwc.2015.2421330
|View full text |Cite
|
Sign up to set email alerts
|

Automatic, Calibrated and Accurate Measurement of S-Parameters in Climatic Chamber

Abstract: Abstract-When measuring RF or microwave devices under a temperature profile inside a climatic chamber, one of the main problems lies in the impossibility to have the network analyzer calibrated for all the temperatures measured along the profile. Typically, the calibration is performed just at room temperature, assuming that there is going to be an error in the rest of the measured temperatures. That error will be higher the further we are from room conditions. In this work, we present a systematic procedure f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 6 publications
(4 reference statements)
0
7
0
Order By: Relevance
“…In fact, the electric responses of these three elements of the calkit were measured at each one of the target temperatures. Thereafter, these measurements are used to calibrate the responses of the four different filters by using a Matlab program, that allows to obtain the corrected measurement at each one of the temperatures following the procedure described in [38].…”
Section: A Set-up For Tests Under Atmospheric Pressure Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…In fact, the electric responses of these three elements of the calkit were measured at each one of the target temperatures. Thereafter, these measurements are used to calibrate the responses of the four different filters by using a Matlab program, that allows to obtain the corrected measurement at each one of the temperatures following the procedure described in [38].…”
Section: A Set-up For Tests Under Atmospheric Pressure Conditionsmentioning
confidence: 99%
“…Content may change prior to final publication. Framework, obtaining a final value of 2200 ppm/ • C. Table 6 provides a comparative study of the results for the SIW, ADLS, ESIW and ESICL filter prototypes presented in this work, together with the results of a similar filter manufactured in WR42 rectangular waveguide [38], an ESIW filter presented in [36], and self-compensated SIW and AFSIW filters presented, respectively, in [35] and [36].…”
Section: Insertion Loss Analysismentioning
confidence: 99%
“…Because of the strong push in digital communications for satellite and terrestrial applications, RF measurement technology has improved dramatically in recent years [86], [141]. Almost all signal analyzer available in the market today are able to capture the amplitude and phase information of an RF signal, known as IQ data.…”
Section: Discussionmentioning
confidence: 99%
“…The main contribution of this novel method is that, instead of calibrating the measurement using the VNA built-in routine, the calibration is performed after taking all the acquisitions within the temperature profile. Hence the approach is [141]:…”
Section: Operation Principlementioning
confidence: 99%
“…The measurement setup was not calibrated before measuring the filters since the properties of the test bench can change with temperature. To address this, the standards of the calibration kits were also submitted to the thermal test, and the resulting measurements were used to calibrate the response of the two devices by following the procedure outlined in [129].…”
Section: Experimental Setup and Measurement Proceduresmentioning
confidence: 99%