2016
DOI: 10.1515/jtam-2016-0010
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Bone Drilling – More Precise, Reliable and Safe Manipulation in the Orthopaedic Surgery

Abstract: Abstract. Bone drilling manipulation often occurs in the orthopaedic surgery. By statistics, nowadays, about one million people only in Europe need such an operation every year, where bone implants are inserted. Almost always, the drilling is performed handily, which cannot avoid the * Corresponding author e-mail: george@imbm.bas.bg. Unauthenticated Download Date | 5/9/18 11:41 PM 52 G. Boiadjiev, R. Kastelov, T. Boiadjiev, K. Delchev, K. Zagurski subjective factor influence. The question of subjective factor … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 17 publications
(26 reference statements)
0
4
0
Order By: Relevance
“…The drilling of the first cortex ended at 509 AU (the fourth drilling stage) and the drilling automatically stopped (drill speed and feed rate were equal to 0) (the fifth drilling stage) according to the auto-stop criterion. 19,23 After pressing the start button again the drilling process started at 817 AU. First drill speed was 1000 rpm; second – (along 2 mm distance – from 818 to 892 AU) the drill bit movement was executed with feed speed of 2 mm/s.…”
Section: Resultsmentioning
confidence: 99%
“…The drilling of the first cortex ended at 509 AU (the fourth drilling stage) and the drilling automatically stopped (drill speed and feed rate were equal to 0) (the fifth drilling stage) according to the auto-stop criterion. 19,23 After pressing the start button again the drilling process started at 817 AU. First drill speed was 1000 rpm; second – (along 2 mm distance – from 818 to 892 AU) the drill bit movement was executed with feed speed of 2 mm/s.…”
Section: Resultsmentioning
confidence: 99%
“…The experiments were executed using the Orthopaedic bone-Drilling Robot 'ODRO' [13][14][15]. The executive module, its power and control block and structure drawing are shown in Figures 3-5, respectively.…”
Section: Drilling Systemmentioning
confidence: 99%
“…The algorithm for preliminary set depth execution (precision is 0.1 mm) is discussed in details in [9].…”
Section: Robotized System Odro-2mentioning
confidence: 99%
“…The drilling process depends on lots of parameters, but the most important one is the thrust force, applied during the drilling execution [9]. It influences both the precision and the temperature.…”
Section: Introductionmentioning
confidence: 99%