2014
DOI: 10.1016/j.bspc.2014.06.010
|View full text |Cite
|
Sign up to set email alerts
|

Automatic artifact removal from GFR measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 24 publications
1
10
0
Order By: Relevance
“…We used a three-compartment kinetic model with linear correction to determine the GFR in mice. This model covers the injection process, the plasma volume, and the interstitial compartment allowing further refinement by correcting for shifts observed occasionally during measurements ( 37 ). After injecting FITC-sinistrin into a mouse that was fed a control diet (control) for 14 days, the fluorescent signal quickly increased at the beginning and descends down to the initial baseline level as it gets filtered by the kidneys after approximately 90 min.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…We used a three-compartment kinetic model with linear correction to determine the GFR in mice. This model covers the injection process, the plasma volume, and the interstitial compartment allowing further refinement by correcting for shifts observed occasionally during measurements ( 37 ). After injecting FITC-sinistrin into a mouse that was fed a control diet (control) for 14 days, the fluorescent signal quickly increased at the beginning and descends down to the initial baseline level as it gets filtered by the kidneys after approximately 90 min.…”
Section: Resultsmentioning
confidence: 99%
“…Other than determining serum BUN and creatinine levels as well as other excretory markers of renal function, these animal studies did not assess GFR as primary endpoint. In our preclinical study, we used the transcutaneous GFR system based on the fluorescent tracer FITC-sinistrin, which is a precise method for repeated measurements in conscious and unrestricted mice to calculate the GFR ( 21 , 22 , 35 , 37 ). Fresolimumab, a TGFβ neutralizing antibody did not elicit any positive effect on the GFR in a randomized control trial including 416 patients with diabetic kidney disease ( 71 ).…”
Section: Discussionmentioning
confidence: 99%
“…The MPD Studio software package (Mannheim Pharma and Diagnostics GmbH)2 was used to generate the elimination kinetics curve of FITC‐sinistrin from which the t 1/2 of FITC‐sinistrin was calculated using the 1‐COM,5,10 2‐COM,1,10 3‐COM10,29 and 3‐COMB 2,10. The elimination rate constant (λ), an expression of GFR indexed to extracellular fluid volume, was calculated using the following equation.λfalse(minute-1false)=t1/2×lnfalse(2false) where t 1/2 represents the excretion half‐life and ln (2) is the natural logarithm of 2, which is approximately 0.693.…”
Section: Methodsmentioning
confidence: 99%
“…If movement artefact is still of concern, algorithms for artefact removal from obtained signals can be used (see Shmarlouski et al . for detailed discussion) …”
Section: Methodsmentioning
confidence: 99%