2015
DOI: 10.1155/2015/720450
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Artifact Removal from Electroencephalogram Data Based on A Priori Artifact Information

Abstract: Electroencephalogram (EEG) is susceptible to various nonneural physiological artifacts. Automatic artifact removal from EEG data remains a key challenge for extracting relevant information from brain activities. To adapt to variable subjects and EEG acquisition environments, this paper presents an automatic online artifact removal method based on a priori artifact information. The combination of discrete wavelet transform and independent component analysis (ICA), wavelet-ICA, was utilized to separate artifact … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
13
0
5

Year Published

2017
2017
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 24 publications
(26 reference statements)
0
13
0
5
Order By: Relevance
“…These proposed systems aim to explore or improve EEG-based emotion recognition systems. [2,39,41,42,49,50,57,61,63,92,104,108,109,117,131,136,149,152,157,173,174,185,186,189,191,[195][196][197][198][199][200][201][202][203][204][205][206][207][208][209]217,219,[223][224][225]229,[262][263][264][265][266]<...>…”
Section: Monitoringmentioning
confidence: 99%
“…These proposed systems aim to explore or improve EEG-based emotion recognition systems. [2,39,41,42,49,50,57,61,63,92,104,108,109,117,131,136,149,152,157,173,174,185,186,189,191,[195][196][197][198][199][200][201][202][203][204][205][206][207][208][209]217,219,[223][224][225]229,[262][263][264][265][266]<...>…”
Section: Monitoringmentioning
confidence: 99%
“…Одним из наиболее простых и часто используемых является метод на основе визуального поиска артефактов [10,11]. Ме-тод предполагает визуальный (или полуавтоматический) анализ временных реализаций ЭЭГ и поиск артефактов опытным нейрофизиологом.…”
Section: (поступило в редакцию 22 апреля 2017 г в окончательной редаunclassified
“…The cap included electrodes over muscles such as the frontalis, orbicularis and temporalis, and also close to nuchal (upper cervical) muscles. At frequencies above 10-20 Hz, EMG signals are the largest contributors to scalp electrical recordings, with the highest power typically in the range 60-90 Hz (Goncharova et al , 2003, Whitham et al , 2007, Whitham et al , 2008, Zhang et al , 2015. Recent research indicates that this is true even when the subject is relaxed and phasic muscle has been excised from the recordings (Whitham et al , 2007, Whitham et al , 2008, Pope et al , 2009, Yilmaz et al , 2014 .…”
Section: Introductionmentioning
confidence: 99%