Automatic and Simple Method for 99Tc Determination Using a Selective Resin and Liquid Scintillation Detection Applied to Urine Samples

Abstract: (99m)Tc (6.0067 h half-life) is an artificial radionuclide largely used in diagnostic medicine. Its daughter (99)Tc is a beta emitter of great concern because of its long half-life (2.111 × 10(5) years) and presumed mobile behavior in the environment. To monitor the (99)Tc in urine from treated patients, an automatic Lab-on-valve (LOV) system for separation and preconcentration of (99)Tc was developed. TEVA resin was selected since it retains pertechnetate ion selectively from diluted nitric acid solutions. Af… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
14
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 29 publications
0
14
0
Order By: Relevance
“…16 The detection limits in radiometric method depended on the LSC counting time. 17 Another report indicated that 99 Tc was determined by isotope dilution mass spectrometry with 97 Tc as spike. The detection limit of Wang's method by using TIMS for 99 Tc was determined at the concentration below 1 ng g À1 (63 mBq g À1 ), which was much higher than that of this study (1.5 mBq g À1 in 0.25 g sample).…”
Section: Srm Sample Analysismentioning
confidence: 99%
“…16 The detection limits in radiometric method depended on the LSC counting time. 17 Another report indicated that 99 Tc was determined by isotope dilution mass spectrometry with 97 Tc as spike. The detection limit of Wang's method by using TIMS for 99 Tc was determined at the concentration below 1 ng g À1 (63 mBq g À1 ), which was much higher than that of this study (1.5 mBq g À1 in 0.25 g sample).…”
Section: Srm Sample Analysismentioning
confidence: 99%
“…Such devices allow the automatic separation and pre-concentration of the analytes prior to the detection, thus increasing reproducibility and repeatability 8 17 18 19 . LOV systems coupled to multisyringe flow pumps have been widely used for the detection of radionuclides, due to the minimization of the reagent consumption and waste generation 8 10 17 18 19 20 . Nevertheless, reported studies regarding online detection at ultra-trace levels are sparse 8 17 .…”
Section: Introductionmentioning
confidence: 99%
“…Such devices allow the automatic separation and pre-concentration of the analytes prior to the detection, thus increasing reproducibility and repeatability 8,17,18,19 . LOV systems coupled to multisyringe flow pumps have been widely used for the detection of radionuclides, due to the minimization of the reagent consumption and waste generation 8,10,17,18,19,20 . Nevertheless, reported studies regarding online detection at ultra-trace levels are sparse 8,17 .…”
Section: Introductionmentioning
confidence: 99%