2002
DOI: 10.1136/bjo.86.7.801
|View full text |Cite
|
Sign up to set email alerts
|

Automated tri-image analysis of stored corneal endothelium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
52
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 50 publications
(52 citation statements)
references
References 30 publications
0
52
0
Order By: Relevance
“…The authors of [16] have developed an analyser with tools for automatic error detection and correction, and for measuring endothelial cell density (ECD) and performing morphometry on multiple zones of three images of the endothelial mosaic.…”
Section: Current Technical Endothelium Related Researchmentioning
confidence: 99%
“…The authors of [16] have developed an analyser with tools for automatic error detection and correction, and for measuring endothelial cell density (ECD) and performing morphometry on multiple zones of three images of the endothelial mosaic.…”
Section: Current Technical Endothelium Related Researchmentioning
confidence: 99%
“…The process is achieved by a closing-opening morphological filtering using the GAN sets with the luminance criterion in the CLIP framework, followed by a watershed transformation. A comparison with the results provided by the SAMBA™ software, whose process is achieved by thresholding, filtering and skeletonization (Gain et al, 2002), is proposed (Fig. 11).…”
Section: Application To Human Endothelial Cornea Cell Optical Imagesmentioning
confidence: 99%
“…Ex vivo controls are done by optical microscopy on corneal button before grafting. That image acquisition equipment give gray tones images which are segmented (Gavet & Pinoli, 2008), for example by the SAMBA™ software (Gain et al, 2002), into regions representing cells. These ones are used to compute statistics in order to quantify the corneal quality before transplantation.…”
Section: Application To Human Endothelial Cornea Cell Optical Imagesmentioning
confidence: 99%
“…The process is achieved by a closing-opening morphological filtering using the GAN sets with the luminance criterion in the CLIP framework, followed by a watershed transformation, denoted W . A comparison with the results provided by the SAMBA™ software, whose process is achieved by thresholding, filtering and skeletonization [22], is proposed (Fig. 5).…”
Section: Image Segmentationmentioning
confidence: 99%
“…Ex vivo controls are done by optical microscopy on corneal button before grafting. That image acquisition equipment give gray tones images which are segmented, for example by the SAMBA™ software [22], into regions representing cells. These ones are used to compute statistics in order to quantify the corneal quality before transplantation.…”
Section: Image Segmentationmentioning
confidence: 99%