2012
DOI: 10.1016/j.jsb.2011.12.004
|View full text |Cite
|
Sign up to set email alerts
|

Automated tracing of microtubules in electron tomograms of plastic embedded samples of Caenorhabditis elegans embryos

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
109
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 104 publications
(109 citation statements)
references
References 29 publications
0
109
0
Order By: Relevance
“…This proved more challenging, as the templates did not always find the inside of tubes but on occasion aligned with neighboring microtubules (or outside noise), resulting in unstable traces that would require manual intervention. After completion of this work a paper appeared which describes such expert feedback during an interactive tracing of microtubules (Weber et al, 2012). Our approach currently lacks a correction for microtubule-specific ‘missing wedge’ artifacts as proposed by Weber et al (2012), which we plan to add in a future software release.…”
Section: Discussionmentioning
confidence: 99%
“…This proved more challenging, as the templates did not always find the inside of tubes but on occasion aligned with neighboring microtubules (or outside noise), resulting in unstable traces that would require manual intervention. After completion of this work a paper appeared which describes such expert feedback during an interactive tracing of microtubules (Weber et al, 2012). Our approach currently lacks a correction for microtubule-specific ‘missing wedge’ artifacts as proposed by Weber et al (2012), which we plan to add in a future software release.…”
Section: Discussionmentioning
confidence: 99%
“…We assumed that this distortion primarily compensates the distortion of the imaging process. For the tracing, the error was previously analysed for reconstructions of C. elegans centrosomes63. Although the spindle data is larger, the tomogram content is similar to the centrosome data sets, and thus we assumed that the error lies in the same range of 5–10%.…”
Section: Methodsmentioning
confidence: 99%
“…Once a fiber was fully traced, all points near its centerline were removed from the buffer, and the process was repeated until the buffer emptied. The template matching and tracing algorithm are described in Weber et al (2012) and Rigort et al (2012). By construction, no branching can occur between the fibers.…”
Section: Fiber Segmentationmentioning
confidence: 99%