2003
DOI: 10.1177/002215540305100503
|View full text |Cite
|
Sign up to set email alerts
|

Automated Selection of DAB-labeled Tissue for Immunohistochemical Quantification

Abstract: The increased use of immunohistochemistry (IHC) in both clinical and basic research settings has led to the development of techniques for acquiring quantitative information from immunostains. Staining correlates with absolute protein levels and has been investigated as a clinical tool for patient diagnosis and prognosis. For these reasons, automated imaging methods have been developed in an attempt to standardize IHC analysis. We propose a novel imaging technique in which brightfield images of diaminobenzidene… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
143
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 177 publications
(146 citation statements)
references
References 36 publications
(95 reference statements)
3
143
0
Order By: Relevance
“…Four images were acquired from randomly selected locations in each slide. Random RGB images were converted to 8-bit images for the quantification of the DAB signal to obtain the integrated density parameters (38,39).…”
Section: Methodsmentioning
confidence: 99%
“…Four images were acquired from randomly selected locations in each slide. Random RGB images were converted to 8-bit images for the quantification of the DAB signal to obtain the integrated density parameters (38,39).…”
Section: Methodsmentioning
confidence: 99%
“…In brief, the red, green, and blue channels for the 24-bit bright field DAB-labeled images were normalized by the sum of the three channels. Pixel values for eight-bit images were calculated using a published formula that allows for maximal separation of DAB-stained pixels from the background tissue: 255 * blue/ (red + green + blue) [5]. CD68-positive macrophages were quantified in each image (9200) of the stained tissue sections with the aid of Image-Pro Plus 6.0 (Media Cybernetics, Silver Spring, MD, USA).…”
Section: Imaging and Analysismentioning
confidence: 99%
“…Tumor-specific areas were exported for analysis in the Metamorph software package (MDS Analytical Technologies, ON, Canada) as individual 8-bit images. The brown DAB-specific staining was isolated from the hematoxylin counterstain using a blue-normalization algorithm as described by Brey et al (2003). A segmentation algorithm identified vessels and removed noise on the basis of size and shape.…”
Section: Immunohistochemistrymentioning
confidence: 99%