2002
DOI: 10.1046/j.1423-0410.2002.00177.x
|View full text |Cite
|
Sign up to set email alerts
|

Automated screening of blood donations for hepatitis C virus RNA using the Qiagen BioRobot 9604 and the Roche COBAS HCV Amplicor assay

Abstract: This combination of methods results in an assay with a high sample throughput, little 'hands-on' time and fast turnaround time that is also sufficiently sensitive to allow testing of pools of up to 96 samples at a time. These methods have been successfully introduced into routine use within the NBS for release of blood components with a shelf-life of longer than 24 h.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
18
0

Year Published

2004
2004
2018
2018

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(19 citation statements)
references
References 22 publications
(23 reference statements)
1
18
0
Order By: Relevance
“…55 Qualitative PCR was performed using the Amplicor HCV v2.0 MWP assay (Roche Molecular Systems, Pleasanton, CA, USA) with an automated nucleic acid extraction using the BioRobot 9604 (Quiagen, Hilden, Germany). 56 Results are expressed as IU ml -1 (1 IU = approximately 5 RNA copies). Viral genotyping was performed using restriction fragment length polymorphism (RFLP) of the 5' non-coding region.…”
Section: Virologymentioning
confidence: 99%
“…55 Qualitative PCR was performed using the Amplicor HCV v2.0 MWP assay (Roche Molecular Systems, Pleasanton, CA, USA) with an automated nucleic acid extraction using the BioRobot 9604 (Quiagen, Hilden, Germany). 56 Results are expressed as IU ml -1 (1 IU = approximately 5 RNA copies). Viral genotyping was performed using restriction fragment length polymorphism (RFLP) of the 5' non-coding region.…”
Section: Virologymentioning
confidence: 99%
“…Due to an increasing demand for molecular tests and for taking advantage of real-time PCR, a fully automated extraction system is considered a prerequisite (18,19,36). Several solutions for nucleic acid (NA) extraction on automated platforms have recently been evaluated for the diagnosis of viral infections (9,11,15,17,20,22,26,27). The COBAS AmpliPrep system (CAP; Roche Diagnostics) is a new instrument designed for rapid high-throughput purification of DNAs and RNAs from biological fluids (such as serum and plasma) (5,14,19,31,33,34).…”
mentioning
confidence: 99%
“…Automation of viral nucleic acid detection using silica magnetic bead technology has been reported for enteroviruses, hepatitis B, hepatitis C, Epstein-Barr virus, herpes simplex virus, human papillomavirus, influenza B and SARS virus (Cheng et al, 2004;Cuschieri et al, 2003;Espy et al, 2001;Fafi-Kremer et al, 2004;Grant et al, 2002;Knepp et al, 2003;Petrich et al, 2006;Shi et al, 2001). This study applies automation using magnetic beads to influenza A detection.…”
Section: Discussionmentioning
confidence: 99%