1997
DOI: 10.1109/23.603709
|View full text |Cite
|
Sign up to set email alerts
|

Automated particulate sampler for Comprehensive Test Ban Treaty verification (the DOE radionuclide aerosol sampler/analyzer)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

1998
1998
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(7 citation statements)
references
References 1 publication
0
7
0
Order By: Relevance
“…For the 238 Fig. 4 Installation of the RASA System at "RN 33" (Mount Schauinsland) observation of particle bound radionuclides for the IMS an automatic system RASA (Radionuclide Aerosol Sampler and Analyzer), which was developed at Pacific Northwest National Laboratory (PNNL) in Richland, USA [4], has been installed and has now started routine operation. The air flow is between 800 and 1000 m 3 h -1 and the reached MDC is below 10 µBq m -3 for 140 Ba.…”
Section: Comprehensive Nuclear-test-ban Treaty (Ctbt)mentioning
confidence: 99%
“…For the 238 Fig. 4 Installation of the RASA System at "RN 33" (Mount Schauinsland) observation of particle bound radionuclides for the IMS an automatic system RASA (Radionuclide Aerosol Sampler and Analyzer), which was developed at Pacific Northwest National Laboratory (PNNL) in Richland, USA [4], has been installed and has now started routine operation. The air flow is between 800 and 1000 m 3 h -1 and the reached MDC is below 10 µBq m -3 for 140 Ba.…”
Section: Comprehensive Nuclear-test-ban Treaty (Ctbt)mentioning
confidence: 99%
“…The system is located at the BfS Schauinsland monitoring station RN33 (altitude 1200 m, 47.91N, 7.91E). It takes daily high volume (approximately 24,000 m 3 ) air filter samples which are analysed with a high purity germanium detector starting after a 24 h filter period during which short lived radon progeny decays [9].…”
Section: Example 1: Exclusion Of 140 Ba When 140 La Is Measuredmentioning
confidence: 99%
“…Due to the low net counting rates, this is done by calculating the Bayesian confidence (or credibility) limits given by Eqs. (9) and (10) using the solution vector and covariance matrix provided by the Single Value Decomposition algorithm.…”
Section: Example 2: Gamma-spectroscopic Xenon Measurementsmentioning
confidence: 99%
“…The IMS radionuclide station RN33 Schauinsland is instrumented with a RASA high volume aerosol sampler and analyzer, which has been described technically by Bowyer et al (1997), and with an automatic SPALAX noble gas sampler and analyzer (Fontaine et al, 2004).…”
Section: Introductionmentioning
confidence: 99%