1997
DOI: 10.1016/s0378-4347(96)00345-3
|View full text |Cite
|
Sign up to set email alerts
|

Automated on-line solid-phase extraction-gas chromatography with nitrogen-phosphorus detection: determination of benzodiazepines in human plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

1997
1997
2008
2008

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 48 publications
(24 citation statements)
references
References 14 publications
0
24
0
Order By: Relevance
“…Sample preparation techniques involve SPE [36,40], automated on-line SPE [34], SPME [23,24,33], on-line dialysis [37,38], direct LC analysis using restricted access extraction materials [43,44], column switching techniques [45][46][47][48], as well as liquid phase microextraction [32].…”
Section: Introductionmentioning
confidence: 99%
“…Sample preparation techniques involve SPE [36,40], automated on-line SPE [34], SPME [23,24,33], on-line dialysis [37,38], direct LC analysis using restricted access extraction materials [43,44], column switching techniques [45][46][47][48], as well as liquid phase microextraction [32].…”
Section: Introductionmentioning
confidence: 99%
“…For a more detailed operation of the operation of the loop-type interface the reader should consult ref. [29].…”
Section: On-line Spe-gc-fid; Configuration Amentioning
confidence: 99%
“…First, an earlier reported on-line ASPEC-GC approach with a loop-type interface was tested [29]. Aliquots of the final eluate (1.0 ml) in ethyl acetate were injected at a temperature of 110 "C. It should be noted that, with this procedure, only a rough drying step was used, viz.…”
Section: Configuration A: Loop-type Interjfacementioning
confidence: 99%
See 1 more Smart Citation
“…[8][9][10][11] The representative LVI methods were a programmable temperature vaporizing (PTV) injection method [12][13][14] and a largevolume on-column injection method. 15,16 Also, other available methods were loop-type, 17,18 vapor-overflow 19,20 and concurrent solvent recondensation (CSR) 21 techniques. In the conventional PTV injection method, the sample is evaporated in the inlet, and during sample introduction the solvent can be eliminated via a split outlet, while higher boiling-point analytes are retained and subsequently transferred to the separating column in the splitless mode.…”
Section: Introductionmentioning