1976
DOI: 10.1021/ac60365a051
|View full text |Cite
|
Sign up to set email alerts
|

Automated method for the determination of total and inorganic mercury in water and wastewater samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
22
1

Year Published

1978
1978
2015
2015

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(24 citation statements)
references
References 25 publications
1
22
1
Order By: Relevance
“…Lo and Wai (1975) measured a 95-percent loss of 203Hg from a 5pg/L solution after 21 days of storage in a polyethylene container, 77 percent of which was adsorbed on the container walls and 18 percent lost by volatilization. Coyne and Collins (1972) noted up to 40-percent loss of mercury from creek and distilled water within 4 h. El- Awady, et al (1976) noted 20 percent of the mercury in a 3-j.tgfL distilled-water solution was lost within 10 mm of its preparation and 60 percent was lost over a period often days.…”
Section: Methods Of Sample Preservationmentioning
confidence: 99%
See 1 more Smart Citation
“…Lo and Wai (1975) measured a 95-percent loss of 203Hg from a 5pg/L solution after 21 days of storage in a polyethylene container, 77 percent of which was adsorbed on the container walls and 18 percent lost by volatilization. Coyne and Collins (1972) noted up to 40-percent loss of mercury from creek and distilled water within 4 h. El- Awady, et al (1976) noted 20 percent of the mercury in a 3-j.tgfL distilled-water solution was lost within 10 mm of its preparation and 60 percent was lost over a period often days.…”
Section: Methods Of Sample Preservationmentioning
confidence: 99%
“…Compounding the problem of preserving mercury in solution is the need for mercury to be in a form that can be reduced and analyzed by cold vapor atomic-absorption spectrometry. Organic mercury must be converted to ionic mercury (El-Awady, et al, 1976), and the method of preservation must not interfere with the reduction of aqueous mercury by stannous chloride during analysis. Only the fraction of reduced mercury that is partitioned to the gas phase is measured by cold vapor atomic-absorption spectrometry (Koirtyohann and Kahlil, 1976).…”
Section: Methods Of Sample Preservationmentioning
confidence: 99%
“…[48][49][50][51][52][53][54][55] Iskander et al 43 applied flameless atomic absorption to a sulfuric acid-nitric acid digest of the sample following reduction with potassium permanganate, potassium persulfate, and stannous chloride. [48][49][50][51][52][53][54][55] Iskander et al 43 applied flameless atomic absorption to a sulfuric acid-nitric acid digest of the sample following reduction with potassium permanganate, potassium persulfate, and stannous chloride.…”
Section: Atomic Absorption Spectrometrymentioning
confidence: 99%
“…Another partial explanation may result from the use of nitric acid as the singular preservation agent used by the Survey. Several investigators have shown that nitric acid alone is insufficient for the preservation of mercury in dilute solutions (El-Awady, Miller and Carter, 1976;Feldman, 1974). Most samples failing the precision test and not containing SRWS 73 had values that were less than the MPV.…”
Section: Almost All Of the Individual Aluminum Analyses Showing Lack mentioning
confidence: 99%