2011
DOI: 10.1016/j.chroma.2011.03.049
|View full text |Cite
|
Sign up to set email alerts
|

Automated method for targeting analysis of prostanoids in human serum by on-line solid-phase extraction and liquid chromatography–mass spectrometry in selected reaction monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…Ferreiro-Vera et al described simultaneous measurement of different inflammation biomarkers from human serum and human plasma and reported concentrations of PGF 2α and PGE 2 as 10.3 and 0.17 ng/ml in plasma [35] and 0.11 ng/ml for PGE 2 [36] in serum which are within our standard calibration range of 0.104 - 33.3 ng/ml. LOQs reported in their method as 46, 138 and 188 pg (on column) for PGF 2α , PGE 2 and PGD 2 were however found to be higher than our method.…”
Section: Discussionmentioning
confidence: 88%
See 1 more Smart Citation
“…Ferreiro-Vera et al described simultaneous measurement of different inflammation biomarkers from human serum and human plasma and reported concentrations of PGF 2α and PGE 2 as 10.3 and 0.17 ng/ml in plasma [35] and 0.11 ng/ml for PGE 2 [36] in serum which are within our standard calibration range of 0.104 - 33.3 ng/ml. LOQs reported in their method as 46, 138 and 188 pg (on column) for PGF 2α , PGE 2 and PGD 2 were however found to be higher than our method.…”
Section: Discussionmentioning
confidence: 88%
“…These include PGD 2 , PGJ 2 , PGE 2 , 15-d-PGD 2 , PGA 2 , 15-d-PGJ 2 , PGF 2α , PGF 1α , 11β-PGF 2α , 6-keto-PGF 1α , and 11-d-TXB 2 . Several of these metabolites have been previously detected in different matrices such as cell cultures [32, 33], plasma/serum [35-37], urine [34, 39], rat kidney [43]. Masoodi et al [39] and Yue et al [44] reported measurements of prostanoids in rat brain or cortical tissue.…”
Section: Discussionmentioning
confidence: 99%
“…1.B) [33][34][35]. In this configuration, two cartridges with the same sorbent are put in serial; hence the retention capability of the C8 SPE sorbent is evaluated by comparison of the amount of analyte retained in both cartridges.…”
Section: Recovery Factormentioning
confidence: 99%
“…LC‐MS/MS is an excellent tool to monitor products of the eicosanoid degradation pathways as reported in the literature . This arrangement is especially useful because, apart from avoiding derivatization, the analysis can be automated by on‐line sample preparation and determination, particularly when sample preparation is based on SPE.…”
Section: Introductionmentioning
confidence: 99%