2019
DOI: 10.1107/s2052520619006711
|View full text |Cite
|
Sign up to set email alerts
|

Automated electron diffraction tomography – development and applications

Abstract: Electron diffraction tomography (EDT) has gained increasing interest, starting with the development of automated electron diffraction tomography (ADT) which enables the collection of three-dimensional electron diffraction data from nano-sized crystals suitable for ab initio structure analysis. A basic description of the ADT method, nowadays recognized as a reliable and established method, as well as its special features and general applicability to different transmission electron microscopes is provided. In ad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
38
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 40 publications
(39 citation statements)
references
References 93 publications
1
38
0
Order By: Relevance
“…The given uncertainties should be considered as rough estimates. Inelastic scattering, an insufficiently sensitive detector and thus difficulties in the background correction do not allow a more precise disorder analysis of this material yet (Kolb et al, 2019). It is worth mentioning that polymorph III has not been taken into account for the disorder simulations presented here, since these subtleties are not yet distinguishable from 3D ED data at the time of writing.…”
Section: All Layersmentioning
confidence: 97%
See 3 more Smart Citations
“…The given uncertainties should be considered as rough estimates. Inelastic scattering, an insufficiently sensitive detector and thus difficulties in the background correction do not allow a more precise disorder analysis of this material yet (Kolb et al, 2019). It is worth mentioning that polymorph III has not been taken into account for the disorder simulations presented here, since these subtleties are not yet distinguishable from 3D ED data at the time of writing.…”
Section: All Layersmentioning
confidence: 97%
“…Nevertheless, the integrated zone image (Fig. S9) was reconstructed with the Matlab-based script diffuse_extractor (Kolb et al, 2019) and the extracted zone shows diffuse scattering along the 00l reflections.…”
Section: Disorder Analysis Of Rub-5mentioning
confidence: 99%
See 2 more Smart Citations
“…9). A detailed description of this method is given by Kolb, Krysiak & Plana-Ruiz (2019), which is included in the special issue on electron crystallography published in Acta Crystallographica Section B (Hadermann & Palatinus, 2019).…”
Section: Quantitative Treatment Of Disordermentioning
confidence: 99%