2019
DOI: 10.1109/access.2019.2908183
|View full text |Cite
|
Sign up to set email alerts
|

Augmented Sensitivity Estimation Based Voltage Control Strategy of Active Distribution Networks With PMU Measurement

Abstract: The application of synchronized phasor measurement technology at distribution networks provides new options for voltage-to-power sensitivity estimation and voltage regulation. An augmented sensitivity estimation-based voltage control strategy with a phasor measurement unit (PMU) measurement is proposed for active distribution networks (ADNs). The voltage control records are extracted from historical synchronized phasor measurements. The voltage-to-power sensitivities reflecting the relationship of voltage chan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 34 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…In (Li et al, 2018), a fast sensitivity based preventive control selection method was proposed for online voltage stability assessment. Reference (Su et al, 2019) proposed a measurement based voltage control method for distribution networks combined with the sensitivity estimation. In (Gupta and Kumar, 2022), the optimal location and sizing of each DG were obtained by sensitivity based techniques.…”
Section: Introductionmentioning
confidence: 99%
“…In (Li et al, 2018), a fast sensitivity based preventive control selection method was proposed for online voltage stability assessment. Reference (Su et al, 2019) proposed a measurement based voltage control method for distribution networks combined with the sensitivity estimation. In (Gupta and Kumar, 2022), the optimal location and sizing of each DG were obtained by sensitivity based techniques.…”
Section: Introductionmentioning
confidence: 99%
“…Thanks to the increasing adoption of monitoring systems such as smart meters in present distribution networks, measurement-based/data-driven/model-less control schemes can be an alternative. This leads to the second kind of voltage control scheme often referred to as measurementbased schemes [7], [10], [11], [12], [13]. These schemes are used for real-time voltage control where the network model is inferred from the measurements.…”
Section: Introductionmentioning
confidence: 99%
“…By introducing the concept of voltage-to-power sensitivity, conducting a numerical linearization around the operating point, a linear relationship between node power injection and voltage is established to improve the calculation efficiency. Voltage-to-power sensitivity has a clear physical concept that shows the relation of active or reactive power fluctuation in voltage amplitude, which currently has been widely applied in stability analysis [16,17], voltage regulation [18,19], DG hosting capacity [20], optimal allocation [21], and so on. Furthermore, with the development of advanced measurement equipment in distribution networks, such as the micro phasor measurement unit (µPMU), sensitivities can be obtained based on limited measurements [17,22].…”
Section: Introductionmentioning
confidence: 99%