2010
DOI: 10.1055/s-0031-1278361
|View full text |Cite
|
Sign up to set email alerts
|

Augmentation of venous, arterial and microvascular blood supply in the leg by isometric neuromuscular stimulation via the peroneal nerve

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
83
0
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 80 publications
(94 citation statements)
references
References 31 publications
10
83
0
1
Order By: Relevance
“…NMES was compared with leg elevation in one study. 31 Eight studies 32,35,37,38,[40][41][42][43] compared NMES with baseline measurements without NMES. …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…NMES was compared with leg elevation in one study. 31 Eight studies 32,35,37,38,[40][41][42][43] compared NMES with baseline measurements without NMES. …”
Section: Resultsmentioning
confidence: 99%
“…Tucker et al 38 showed that electrical stimulation using 1-40 mA current and 1-5 Hz frequency increased mean peak venous velocity by 50%-260% from baseline.…”
Section: Discussionmentioning
confidence: 99%
“…Neuromuscular electrical stimulation (NMES) devices and intermittent pneumatic compression (IPC) devices have been shown to be effective in improving blood flow (Tucker et al, 2010, Currier et al, 1996, Kaplan et al, 2002. They are often used post-surgery to prevent deep vein thrombosis (DVT) (Goldhaber & Morrison, 2002), in procedures such as total hip replacement (Doran & White,1976); and have been found to reduce oedema in the thigh of total hip replacement patients post-surgery (Faghri et al, 1997).…”
Section: Introductionmentioning
confidence: 99%
“…ЭМС может оказывать воздействие на периваскуляр-ные или тканевые факторы, в том числе и регуляцию вазомоторных процессов [33][34][35][36].…”
Section: механическая перемежающая компрессия нижних конечностейunclassified