2019
DOI: 10.1007/s00402-019-03162-2
|View full text |Cite
|
Sign up to set email alerts
|

Augmentation of plate osteosynthesis for proximal humeral fractures: a systematic review of current biomechanical and clinical studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
34
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(36 citation statements)
references
References 63 publications
0
34
0
1
Order By: Relevance
“…Auto- and allo-grafting represent the most used strategies for PHF augmentation and patient treatment. However, even if good to excellent outcomes have been reported in the literature, these options still lack long-term follow up and comparative studies [ 76 ]. Nevertheless, the main problem of its extensive use is the concerns about possible side donor morbidity of autografts, their availability, and the high costs of allografts.…”
Section: Discussionmentioning
confidence: 99%
“…Auto- and allo-grafting represent the most used strategies for PHF augmentation and patient treatment. However, even if good to excellent outcomes have been reported in the literature, these options still lack long-term follow up and comparative studies [ 76 ]. Nevertheless, the main problem of its extensive use is the concerns about possible side donor morbidity of autografts, their availability, and the high costs of allografts.…”
Section: Discussionmentioning
confidence: 99%
“…Zur Verbesserung des Knochen-Implantate-Interface kann bei fortgeschrittener Osteoporose eine Augmentation der Kopfschrauben mit PMMA-Knochenzement durchgeführt werden. Damit lässt sich eine signifikant verbesserte Fixierung der Schrauben im osteoporotischen Knochen erreichen [22]. Metaphysäre Frakturen können auch mittels intramedullärer Nägel stabilisiert werden.…”
Section: Therapieunclassified
“…Various approaches have been introduced to improve the biomechanical performance of locking plate fixation for osteoporotic proximal humerus fractures. 9 - 11 One of the available options is applying calcium phosphate or poly(methyl methacrylate) (PMMA) bone cement at the tip of cannulated locking screws. Numerous in vitro biomechanical studies have demonstrated enhanced primary stability of proximal humerus plating with cement-augmented screws.…”
Section: Introductionmentioning
confidence: 99%
“…Numerous in vitro biomechanical studies have demonstrated enhanced primary stability of proximal humerus plating with cement-augmented screws. 9 , 12 However, the clinical findings have been controversial regarding the benefit of bone cement augmentation with the proximal humerus internal locking system (PHILOS; DePuy Synthes, Zuchwil, Switzerland). 13 - 15 These variable results may be related to heterogenicity of augmentation techniques and the screw configurations used.…”
Section: Introductionmentioning
confidence: 99%