2021 43rd Annual International Conference of the IEEE Engineering in Medicine &Amp; Biology Society (EMBC) 2021
DOI: 10.1109/embc46164.2021.9630508
|View full text |Cite
|
Sign up to set email alerts
|

Auditory Attention Detection with EEG Channel Attention

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(13 citation statements)
references
References 13 publications
4
9
0
Order By: Relevance
“…On the KUL dataset, BSAnet obtains a relatively high ASAD accuracy of 95.2% (SD: 3.08) for 2 s and 93.7% (SD: 4.02) for 1 s of window. These results are consistent with the previous findings that decoding accuracy positively correlates with the decision window size [10], [19], [20], [25], [29], [30]. The ASAD accuracy degrades to 90.3% (SD: 5.19) for a window of 0.5 s. It is worth noting that BSAnet obtains an acceptable ASAD performance (mean: 84.7%, SD: 6.46) despite a very narrow window of 0.25 s or 250 ms.…”
Section: B Size Of Decision Windowsupporting
confidence: 93%
See 3 more Smart Citations
“…On the KUL dataset, BSAnet obtains a relatively high ASAD accuracy of 95.2% (SD: 3.08) for 2 s and 93.7% (SD: 4.02) for 1 s of window. These results are consistent with the previous findings that decoding accuracy positively correlates with the decision window size [10], [19], [20], [25], [29], [30]. The ASAD accuracy degrades to 90.3% (SD: 5.19) for a window of 0.5 s. It is worth noting that BSAnet obtains an acceptable ASAD performance (mean: 84.7%, SD: 6.46) despite a very narrow window of 0.25 s or 250 ms.…”
Section: B Size Of Decision Windowsupporting
confidence: 93%
“…The performance of the proposed model is evaluated using fivefold cross-validation (CV) in this study [54]. In accordance with previous studies [20], [28], [29], and [30], the ASAD accuracy is defined as the percentage of correctly classified decision windows on the test set. The average performance of the fivefold validation process is reported as the final results.…”
Section: Network Configurationmentioning
confidence: 93%
See 2 more Smart Citations
“…AAD can be achieved based on different cortical activity measurement methods, such as electrocorticography [9], magnetoencephalography [14], and EEG [15][16][17]. Among these measures, the electroencephalography (EEG)-based one has superiority because of its high temporal resolution, noninvasive mode, and great maneuverability [15,[18][19][20][21][22][23]. The traditional linear AAD models based on EEG analysis can be classified into three types: (a) The backward models (also called decoding model), which map from EEG signals to acoustic features [24].…”
Section: Introductionmentioning
confidence: 99%