2002
DOI: 10.1107/s0021889801018350
|View full text |Cite
|
Sign up to set email alerts
|

Attainment of near-hydrostatic compression conditions using the Paris–Edinburgh cell

Abstract: By means of a straightforward modi®cation to the Paris±Edinburgh cell gasket con®guration, it is now possible to utilize¯uid pressure-transmitting media up to at least 9 GPa. Test data on various representative samples are presented, discussed and contrasted with typical results obtained using the earlier gasket arrangement and Fluorinert pressure-transmitting medium. For the case of deuterated urea, the signi®cant improvement in compression conditions revealed the existence of two new structural phases (IV an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

5
132
0
2

Year Published

2003
2003
2014
2014

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 162 publications
(139 citation statements)
references
References 18 publications
5
132
0
2
Order By: Relevance
“…25,26 In addition to the powder under study, a small Pb sphere (ca. 0.8 mm diameter) was included in the standard null-scattering TiZr gasket 27 for use as a pressure marker, along with a few drops of a 4:1 by volume mixture of perdeuterated methanol/ethanol pressure transmitting medium. 28 Using the conventional collection mode of Pearl, data were collected using high resolution banks centred at 90 , corresponding to a d-spacing range of 0.3 to 4.15 Å .…”
Section: Methodsmentioning
confidence: 99%
“…25,26 In addition to the powder under study, a small Pb sphere (ca. 0.8 mm diameter) was included in the standard null-scattering TiZr gasket 27 for use as a pressure marker, along with a few drops of a 4:1 by volume mixture of perdeuterated methanol/ethanol pressure transmitting medium. 28 Using the conventional collection mode of Pearl, data were collected using high resolution banks centred at 90 , corresponding to a d-spacing range of 0.3 to 4.15 Å .…”
Section: Methodsmentioning
confidence: 99%
“…18,19 In this particular cell design, the nonhydrostaticity of the pressure medium also served to reduce stress on the anvils; in its original configuration maximum pressures of only 2-3 GPa could be achieved with hydrostatic pressure media compared to 9-10 GPa with fluorinert. 10 Recent experiments suggest that fluorinert is hydrostatic to 0.6 GPa, 20,21 but evidence for a low hydrostatic limit of fluorinert goes back at least to the work of Decker et al 22 They showed that use of fluorinert completely suppresses the monoclinic-to-rhombohedral phase transition in lead phosphate that normally occurs at 1.8 GPa and had therefore transmitted shear stresses to the lead phosphate sample that stabilized the monoclinic ferroelastic phase. More recently, line broadening in high-pressure neutron powder diffraction experiments has been attributed to the nonhydrostaticity of fluorinert, but estimates of the pressure range at which broadening starts range between 0.7 and 5 GPa.…”
mentioning
confidence: 99%
“…[5][6][7][8][9] Although the degree of line broadening depends sensitively upon a number of factors, including the physical state and the elastic constant tensor of the sample, this limitation of the cell/medium invariably degrades the quality of the resulting diffraction pattern by means of a loss of effective instrumental resolution. 10 The practice of neglecting the nonhydrostatic compression effect and taking the lattice parameter as the average of the lattice parameters calculated from the measured d spacings of the observed reflections results in an overestimation of the lattice parameter and the standard deviation in the lattice parameter. 4 Furthermore, the apparent pressure registered by internal pressure standards can also be affected by nonhydrostatic stresses, 2,3,11-14 resulting in incorrect equation of state parameters being determined from pressure-volume data.…”
mentioning
confidence: 99%
“…Pour les mesures de neutrons, on choisira de préfèrence un liquide non hydrogéné tel que les hydrocarbures perfluorés de la série des Fluorinert (FC-75, mélange FC-84-FC-87 hydrostatique jusque vers 2,3 GPa à l'ambiante [36,41]), ou des mélanges d'alcools deutériés (éthanol-méthanol ou pentane-isopentane) restant liquides jusqu'à des pressions supérieures [26].…”
Section: Les Chambres De Type Piston-cylindre à Milieu Transmetteur Lunclassified