2013
DOI: 10.1016/j.bspc.2013.04.002
|View full text |Cite
|
Sign up to set email alerts
|

Atrial flutter and atrial tachycardia detection using Bayesian approach with high resolution time–frequency spectrum from ECG recordings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(12 citation statements)
references
References 28 publications
0
11
0
Order By: Relevance
“…The VFCDM method has shown higher resolution than any other time-frequency spectrum methods, such as smoothed pseudo Wigner-Ville (SPWV), short-time Fourier transform (STFT) and wavelet transform (WT) methods [25,26,27,28]. Considering a sinusoidal signal x ( t ) to be a narrow band oscillation with an instantaneous amplitude A ( t ), a center frequency f0, a phase ϕ ( t ), and a direct current component dc ( t ): xfalse(tfalse)=dcfalse(tfalse)+Afalse(tfalse)cosfalse(2πf0t+φfalse(tfalse)false)…”
Section: Methodsmentioning
confidence: 99%
“…The VFCDM method has shown higher resolution than any other time-frequency spectrum methods, such as smoothed pseudo Wigner-Ville (SPWV), short-time Fourier transform (STFT) and wavelet transform (WT) methods [25,26,27,28]. Considering a sinusoidal signal x ( t ) to be a narrow band oscillation with an instantaneous amplitude A ( t ), a center frequency f0, a phase ϕ ( t ), and a direct current component dc ( t ): xfalse(tfalse)=dcfalse(tfalse)+Afalse(tfalse)cosfalse(2πf0t+φfalse(tfalse)false)…”
Section: Methodsmentioning
confidence: 99%
“…Based on 12 extracted features, the Bayesian network produced an accuracy rate of 86.25% (Wiggins et al, 2008). Another Bayesian-based method was utilized in analyzing interval ECG signals (Lee, McManus, Bourrell, Sörnmo, & Chon, 2013). A high resolution time-frequency spectral method was developed to process atrial activities.…”
Section: Statistical Modelsmentioning
confidence: 99%
“…A high resolution time-frequency spectral method was developed to process atrial activities. The method produced an accuracy rate of 88% (Lee et al, 2013). In Atoui, Fayn, and Rubel (2010), multiple regression-based methods were used to process ECGs from cardiac patients, while in Iacoviello et al (2007), a linear regression analysis was conducted for ECG monitoring.…”
Section: Statistical Modelsmentioning
confidence: 99%
“…Readers may refer to [16] for more information about particle filters. Lee et al in [17] used a particle filter based framework along with a modified polar EDM in order to extract the atrial signal from ECG for detection of Atrial Flutter (AFL) and Atrial Tachycardia (AT). To overcome the computational complexity of PF, Lin et al in [18] proposed to use a marginalized particle filter (MPF) for ECG denoising and implemented the "triangular" model proposed by SchÖn et al [19].…”
Section: Introductionmentioning
confidence: 99%