2020
DOI: 10.35336/va-2020-e-17-21
|View full text |Cite
|
Sign up to set email alerts
|

Atrial fibrillation cryoballoon ablation in patients with a common pulmonary vein trunk

Abstract: Objective: we aimed to assess the efficacy and safety of pulmonary vein (PV) cryoballoon ablation (CBA) in patients with a common trunk of the pulmonary veins (PVCT).Materials and methods: We performed a retrospective analysis of 596 primary PV CBA procedures using the second-generation cryoballoon (CB) Arctic Front Advance (28 mm). PV anatomy was visualized using direct LA angiography during high-frequency right ventricular pacing. We included forty-nine patients in whom a PVCT was identified. The one-step an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 18 publications
0
2
0
1
Order By: Relevance
“…LAA occluders were successfully implanted in all patients. Periprocedural complications and adverse events during follow‐up were comparable between patients aged < 75 years and ≥75 years 19 . In a prospective LAAC registry of 638 patients in Germany, 402 (63%) were ≥75 years.…”
Section: Discussionmentioning
confidence: 85%
See 1 more Smart Citation
“…LAA occluders were successfully implanted in all patients. Periprocedural complications and adverse events during follow‐up were comparable between patients aged < 75 years and ≥75 years 19 . In a prospective LAAC registry of 638 patients in Germany, 402 (63%) were ≥75 years.…”
Section: Discussionmentioning
confidence: 85%
“…Periprocedural complications and adverse events during follow‐up were comparable between patients aged < 75 years and ≥75 years. 19 In a prospective LAAC registry of 638 patients in Germany, 402 (63%) were ≥75 years. The success rate of the procedure was high (97.6%).…”
Section: Discussionmentioning
confidence: 99%
“…Такие варианты строения могут затруднять надежную обтурацию ЛВ и достижение плотного контакта баллона с эндокардом. В нашем исследовании частота выявления общего коллектора ЛВ составила 27 % (38 пациентов), что сопоставимо с ранее опубликованными наблюдениями (8,2-37 %) [17][18][19]. Кроме того, многофакторный анализ продемонстрировал, что общий коллектор ЛВ был независимым ФР неэффективности КБА.…”
Section: протокол кбаunclassified