1983
DOI: 10.1007/bf02455930
|View full text |Cite
|
Sign up to set email alerts
|

Atrial activity during thePR segment of the MCG

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
0
0
1

Year Published

1989
1989
2023
2023

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 7 publications
0
0
0
1
Order By: Relevance
“…Although a preliminary magnetic measurement of the PR interval's MF had been reported in 1978 (116), high-resolution (HR) MCG recordings of the PR segment were carried out independently both with unshielded MCG and in MSR since the early 1980s (27,33,117,118). The physiological interpretation of HR MCG waveforms of the PR interval was controversial (34,(119)(120)(121)(122) until the nature of the so-called "ramp-like" pattern recorded during the PR interval (Figure 3A) was definitely clarified within the development of software for automatic MF mapping and interactive subtraction. In fact, by subtracting the atrial repolarization field component from the whole PR interval's MF, a weaker remaining MF generated by sources moving from the AV junction downward along the interventricular septum was identified, consistent with the activation of the His-Purkinje System (123), coherently with the output of a more advanced mathematical model of the normal AV conduction pathways (124)(125)(126) and later by simultaneous MCG and invasive His bundle electrogram recording (127) and by direct comparison of atrial magnetic repolarization field distribution and simultaneous atrial monophasic action potential recording (128) (Figure 3B).…”
Section: Unshielded Mcg: the Pastmentioning
confidence: 99%
“…Although a preliminary magnetic measurement of the PR interval's MF had been reported in 1978 (116), high-resolution (HR) MCG recordings of the PR segment were carried out independently both with unshielded MCG and in MSR since the early 1980s (27,33,117,118). The physiological interpretation of HR MCG waveforms of the PR interval was controversial (34,(119)(120)(121)(122) until the nature of the so-called "ramp-like" pattern recorded during the PR interval (Figure 3A) was definitely clarified within the development of software for automatic MF mapping and interactive subtraction. In fact, by subtracting the atrial repolarization field component from the whole PR interval's MF, a weaker remaining MF generated by sources moving from the AV junction downward along the interventricular septum was identified, consistent with the activation of the His-Purkinje System (123), coherently with the output of a more advanced mathematical model of the normal AV conduction pathways (124)(125)(126) and later by simultaneous MCG and invasive His bundle electrogram recording (127) and by direct comparison of atrial magnetic repolarization field distribution and simultaneous atrial monophasic action potential recording (128) (Figure 3B).…”
Section: Unshielded Mcg: the Pastmentioning
confidence: 99%
“…Os últimos anos proporcionaram mais progressos em investigação clínica [45-48] e também em pesquisa básica [49][50][51][52][53][54] A figura 1.1 mostra esquematicamente o sistema criogênico contido em um dewar de fibra de vidro com superisolamento [67]. O reservatório de hélio líquido, necessário para manter o circuito supercondutor a uma temperatura de 4.20 Kelvin, usualmente mantém o sistema frio por alguns dias.…”
Section: Prefaciounclassified