2021
DOI: 10.1039/d0ja00429d
|View full text |Cite
|
Sign up to set email alerts
|

Atomic emission spectrometry analysis of metals and alloys using a two-jet arc plasma with spark sampling and calibration by solutions

Abstract: For the first time, the injection of solutions into the plasma of a two-jet arc plasmatron was used for the analysis of metals and alloys. Tandem calibration was used for quantitative chemical analysis by the TJP-AES method.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 13 publications
0
9
0
Order By: Relevance
“…The second paper applied the technique to the analysis of steel samples including the reference materials UG-5K and UG-7K. 36 Agreement with certified values was very good. However, it was noticeable that precision was relatively poor.…”
Section: Metalsmentioning
confidence: 97%
See 2 more Smart Citations
“…The second paper applied the technique to the analysis of steel samples including the reference materials UG-5K and UG-7K. 36 Agreement with certified values was very good. However, it was noticeable that precision was relatively poor.…”
Section: Metalsmentioning
confidence: 97%
“…Two publications by Kuptsov et al discussed the optimization of operational parameters 35 and the analysis of steels 36 using a two-jet arc plasmatron using spark ablation . The technique uses much higher power than an ICP (15 kW) and is used to analyse powdered solid samples directly, without recourse to dissolution procedures.…”
Section: Metalsmentioning
confidence: 99%
See 1 more Smart Citation
“…One example, by Kuptsov et al used a two-jet arc plasma with spark sampling and calibration using solutions . 33 Both steel and copper samples were analysed, so this paper was discussed in Section 2.1. The reader is referred there for more detail.…”
Section: Metalsmentioning
confidence: 99%
“…2 Solids analysis 2.1 Direct methods 2.1.1 Arc and spark. In a series of articles, Kuptsov and coworkers [48][49][50] described the analytical capabilities of two-jet arc plasmatron (TJP)-OES using spark ablation. The optimised system was used to obtain accurate, reproducible analysis of metals and alloys with solution calibration.…”
Section: Sample Introductionmentioning
confidence: 99%