2014
DOI: 10.1016/j.ijhydene.2014.05.169
|View full text |Cite
|
Sign up to set email alerts
|

Atom probe tomography observation of hydrogen in high-Mn steel and silver charged via an electrolytic route

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
60
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 59 publications
(62 citation statements)
references
References 33 publications
2
60
0
Order By: Relevance
“…This, however, is usually limited to voltage-mode experiments, as the laser causes complex molecular species, such as ionised molecules of ð 1 HÞ 2 to form. Deuterium studies have been undertaken by several authors [59,64,90,156,204,208], often involving modifications to standard APT systems for introducing hydrogen into samples. These studies have shown that it is possible to image hydrogen within a range of materials; however, the APT is typically limited to only showing localised concentrations on the order of 20 at.…”
Section: Experimental Techniques To Detect Hydrogen In Metalsmentioning
confidence: 99%
“…This, however, is usually limited to voltage-mode experiments, as the laser causes complex molecular species, such as ionised molecules of ð 1 HÞ 2 to form. Deuterium studies have been undertaken by several authors [59,64,90,156,204,208], often involving modifications to standard APT systems for introducing hydrogen into samples. These studies have shown that it is possible to image hydrogen within a range of materials; however, the APT is typically limited to only showing localised concentrations on the order of 20 at.…”
Section: Experimental Techniques To Detect Hydrogen In Metalsmentioning
confidence: 99%
“…However, the low solubility of deuterium within both ferrite and austenite (34) should achieve a higher deuterium content (31). In recent work using this approach no spatial data was shown for steel samples primarily due to diffusion losses.…”
Section: Articlementioning
confidence: 99%
“…Charging was conducted using a 0.1 M NaOH in H 2 O (H as either 1 H, or 2 H for protiated or deuterated experiments respectively), at 2.2 V for 30 s, using an apparatus similar to that in previous works (31). A Keithley 487 pico-ammeter/voltage source was used for power supply and current measurement, and a small camera was used to ensure that samples were inserted into the solution.…”
Section: Articlementioning
confidence: 99%
“…These local compositions match the Z-contrast observations in the STEM-HAADF image, Figure 2a. [43][44][45][46] The important feature of an APT is that it is a spectrometric technique using a microchannel plate (MCP) for detecting ions and measuring their mass-to-charge state ratios (m/n), essentially one ion at a time. The composition of the dark layers was found to be similar to that at the intercolumnar grain boundaries.…”
Section: Tem and Cs-corrected Stem Microstructural And Crystallographmentioning