2020
DOI: 10.1021/acs.analchem.0c02273
|View full text |Cite
|
Sign up to set email alerts
|

Atom Probe Mass Spectrometry of Uranium Isotopic Reference Materials

Abstract: Atom probe tomography (APT)-based isotopic analyses are becoming increasingly attractive for analysis applications requiring small volumes of material and sub-micrometer length scales, such as isotope geochemistry, nuclear safety, and materials science. However, there is an open question within the atom probe community as to the reliability of atom probe isotopic and elemental analyses. Using our proposed analysis guidelines, in conjunction with an empirical calibration curve and a machine learning-based adapt… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 43 publications
(81 reference statements)
0
7
0
Order By: Relevance
“…Experimental observations have shown the isotopic variants of an ion species, e.g., 32,32 S 2 + , 32,33 S 2 + , 32,34 S 2 + , 32,36 S 2 + , 33,33 S 2 + , 33,34 S 2 + , 33,36 S 2 + , 34,34 S 2 + , 34,36 S 2 + , and 36,36 S 2 + , have nominally the same peak form (Meisenkothen et al, 2020a(Meisenkothen et al, , 2020b(Meisenkothen et al, , 2020c. The local spectrum in the region of the family of peaks can thus be approximated as a linear combination of the individual constituent peaks, and an optimization algorithm can be used to determine the "best fit" shape, shared in common by the peaks, and the relative intensities of the peaks.…”
Section: Adaptive Peak Fittingmentioning
confidence: 99%
See 2 more Smart Citations
“…Experimental observations have shown the isotopic variants of an ion species, e.g., 32,32 S 2 + , 32,33 S 2 + , 32,34 S 2 + , 32,36 S 2 + , 33,33 S 2 + , 33,34 S 2 + , 33,36 S 2 + , 34,34 S 2 + , 34,36 S 2 + , and 36,36 S 2 + , have nominally the same peak form (Meisenkothen et al, 2020a(Meisenkothen et al, , 2020b(Meisenkothen et al, , 2020c. The local spectrum in the region of the family of peaks can thus be approximated as a linear combination of the individual constituent peaks, and an optimization algorithm can be used to determine the "best fit" shape, shared in common by the peaks, and the relative intensities of the peaks.…”
Section: Adaptive Peak Fittingmentioning
confidence: 99%
“…The background spectrum under the family of peaks was assumed to be a constant and was approximated by averaging the ion counts in hundreds of bins immediately to the left of the family of peaks. Adaptive peak fitting has been used successfully to provide repeatable and accurate isotopic analyses with filtered single-hit corrected-TOF spectra collected for a variety of materials on a LEAP-4000XSi instrument (Meisenkothen et al, 2020a(Meisenkothen et al, , 2020b(Meisenkothen et al, , 2020c. All of our analyses performed with the adaptive peak fitting used corrected-TOF spectra exported from the IVAS (v 3.8.8) Cal/Recon Wizard (i.e., timing signal-only-based data, prior to hit finding and ion feedback filtering) with a bin width of 0.01 ns.…”
Section: Adaptive Peak Fittingmentioning
confidence: 99%
See 1 more Smart Citation
“…Few APT studies have probed the accuracy and precision of the technique in detail (Prosa et al, 2013b;Meisenkothen et al, 2020a), but this study shows that it is possible to achieve very high precision on Si-isotope fractions. Extending the approach shown here to P-doped silicon, ideally analyzed at higher CSR, would allow one to make reliable measurement of the isotopic abundances for that sample from the Si ++ ions (which do not exhibit hydrides) and use that information to decouple any overlaps at 31 Da.…”
Section: Generalmentioning
confidence: 90%
“…Atom probe tomography (APT) analysis (Bachhav et al, 2021(Bachhav et al, , 2020Meisenkothen et al, 2020) was performed on this fuel to investigate atomic composition from similar regions of the fuel pellet to the STXM FIB sections. Specimens were analyzed at the Center for Advanced Energy Studies (CAES) for APT analysis using a Cameca LEAP 4000XHR.…”
Section: Atom Probe Tomographymentioning
confidence: 99%